www.insigniaproducts.com
19
4.8 Cu. Ft. Electric Convection Range with Steam Cleaning
Connect a 3-wire power cord
1
Disconnect power to the circuit breaker or fuse box before making the electrical connection.
2
Remove the four lower terminal screws from the terminal block.
3
Insert the bracket to the lower terminal block.
4
Insert the colored wires into the bracket. Make sure you match the colors with top colored wires when you connect.
5
Insert the three screws into the lower terminal. No wire is connect to the terminal on the right.
6
Go to Replace the terminal block cover on page 20.
Note:
The metal jumper bracket must be installed between the right two terminals G (Ground) and N (Neutral), then tightened in
place.
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
L1
L2
N
G
Bond
Neutral
Live 2
Live 1
Terminal block
Bond
Live 2
Live 1
Red
Black
White
Green
Red
Black
White
Bracket
Neutral