9
Top Control Dishwasher
www.insigniaproducts.com
Preparing the hot water line
•
The water connection is on the left side of dishwasher.
•
The hot water line may enter the opening from either side, the rear, or the floor within the shaded area.
•
The hot water line may pass through the same hole as the electrical and drain hose. Or, you can drill an additional
1-1/2 in. (3.81 cm) maximum diameter hole for the hot water line.
•
If a power cord with a plug is used, the hot water line may not pass through the same hole as the power cord.
Connecting the water line to the water supply
1
Turn off the water supply.
2
Install a hand shut-off valve in an accessible location, such as under the sink. This is optional, but strongly
recommended, and may be required by local codes.
3
Install the hot water inlet line, using at least 3/8 in. O.D. copper tubing. Route the line as shown in the figure
above and extend it forward at least 18 in. (45.72 cm) from the rear wall of the enclosure.
4
Adjust the water heater to a temperature of from 120° F to 150° F (49° C to 65° C).
5
Flush the water line to clean out any debris.
Note
The hot water pressure must be between 20 and 120 psi.
1-1/2 in. (3.81 cm)
diameter hole (max.)
Shut-off valve
18 in. (45.72 cm) from wall
Hot
5-1/3 - 7-1/3 in.
(13.5-18.5 cm)
from cabinet
Cabinet face
3 in. (7.62 cm) from floor
5-1/3 - 7-1/3 in.
(13.5-18.5 cm)
from cabinet
Water supply
line
Power cable
2-1/2-3-1/2 in. (6.5-9.0 cm)
NS-DWH2_BS8_SS8_NS-DWR2_BS8_WH8_SS8_17-0649_Install MAN_V3_ENG.fm Page 9 Thursday, July 27, 2017 9:21 AM