Control Panel Instructions

 

8

 

9

 

10

 

11

 

Button 1/2 (Sauna Heaters) 

 

Press to activate Sauna heaters. Pressing once will put the heaters on at 100%. Twice = 90%. Three times = 80%. Four 

times = 70% and five times = Off.

 

Button 3(Lights) 

 

Press to cycle through the coloured lights. Each press will change colour until a full cycle is completed and they turn off.

 

Button 4 (Fan) 

 

Press to turn the fan on, press again to turn it off.

 

Button 5 (Time/Temp) 

 

Press to display temp, then cycle through desired temperature setting (max 60°C) using up and down arrows (Buttons 6/8). Press 

again to display time, then cycle through desired time setting (max 99 mins) using up and down arrows (Buttons 6/8).

 

Button 6/8 (Up and Down Arrows) 

 

Use to cycle up or down through various setting options.

 

Button 7 (Play/Pause/Memory) 

 

Use to Play/Pause music through various settings. When searching and tuning the radio, use to save a desired frequency 

to a specific channel.

 

Button 9 (Set)

 

Press and use the arrows (Button 5/11) to manually search. Hold to tune radio stations automatically.

 

Button 10 (Audio Mode) 

 

Press to cycle through the audio options, Radio/MP3/USB/Bluetooth or AUX. To connect the Bluetooth press the Audio 

function (Button 10) until 

BT

’ 

is shown on the control panel. Pair the sauna with your device. Once connected a tone will 

signify the connection has been successful and the Bluetooth icon showing on the panel interface.

 

Button 11 (Alarm)

 

Press to activate the alarm, press again to deactivate it.

 

Button 12 (Power)

 

Use to power the control panel on or off. Also use to unlock he panel (enters lock mode automatically after 60 seconds of inactivity).

 

7

 

6

 

5

 

4

 

3

 

2

 

1

 

12

 

KY1500 (KY0721 BT Panel)

 

Содержание KY1500 Series

Страница 1: ...of your warranty period visit https www insigniashowers com click support and make a warranty claim Spares Replacements Parts Outside of your warranty period visit https www insigniashowers com replac...

Страница 2: ...anel to Back Panel Connection 7 Floor Positioning 8 Heater Cover Install 9 Seat Install 10 Right Side Panel Connection 13 Front Frame Install 14 Door Handle Install 15 Roof Install and Electrics Conne...

Страница 3: ...this booklet with great care to ensure you get the best out of your build and have a Sauna that will last for many years to come Like everything in order to obtain a first class product that will ser...

Страница 4: ...h prefitted RCD unit We leave it this way for you to connect it your own way due to continued additions to current regulations 1 Connect within current laws and IP directives Subject to room location...

Страница 5: ...dle Heater Guard Screw Pack 1 1 1 2 2 2 2 1 1 2 1 VERY IMPORTANT Have you got everything If not please contact the Insignia directly on 01908 317 512 Remember NEVER book your tradesman until everythin...

Страница 6: ...together The cut outs are for the top of the panel for the wires to slot through to the roof 20 x 60mm Screws Slide the two panel pieces together and slot the top and bottom wood securing pieces in p...

Страница 7: ...www insigniashowers com Last Modified 07 10 2021 07 Step 2 Left side panel and back panel connection Lift the side panel locate fixings and once connected push down to secure into position...

Страница 8: ...insigniashowers com Last Modified 07 10 2021 08 Step 3 Slide the floor into position Ensure the plate heaters are towards the front Remove the wood securing it in position for transit and the packagi...

Страница 9: ...com Last Modified 07 10 2021 09 Step 4 Installing heater covers Connect the lights then align the heater cover using a spirit level and connect screw in position using ST50 Screws Do this for both si...

Страница 10: ...www insigniashowers com Last Modified 07 10 2021 10 Step 5 Installing the seats 16 x 30mm Screws...

Страница 11: ...www insigniashowers com Last Modified 07 10 2021 11 Step 6 Installing seats continued Firmly push all rubber hoses together...

Страница 12: ...www insigniashowers com Last Modified 07 10 2021 12 Step 7 Seat Electrics Connect all power from under both seats and then slide into position...

Страница 13: ...www insigniashowers com Last Modified 07 10 2021 13 Step 8 Right Side Panel Installation Lift the side panel locate fixings and once connected push down to secure into position...

Страница 14: ...www insigniashowers com Last Modified 07 10 2021 14 Step 9 Front Frame Installation Lift the front frame locate fixings and meet with each side panel then push down to secure into position...

Страница 15: ...www insigniashowers com Last Modified 07 10 2021 15 Step 10 Installing the door handle and seals...

Страница 16: ...www insigniashowers com Last Modified 07 10 2021 16 Step 11 Installing the roof and connecting power...

Страница 17: ...www insigniashowers com Last Modified 07 10 2021 17 Step 12 Securing the Roof into Position 14 x 60mm Screws...

Страница 18: ...www insigniashowers com Last Modified 07 10 2021 18 Step 13 Securing the Wires to the Roof 20 x 12mm Screws...

Страница 19: ...to cycle up or down through various setting options Button 7 Play Pause Memory Use to Play Pause music through various settings When searching and tuning the radio use to save a desired frequency to a...

Страница 20: ...www insigniashowers com Last Modified 07 10 2021 20 Chair Remote...

Страница 21: ...have a heart condition have low or high blood pressure If you re unsure consult your GP before use 8 If you have any underlying health conditions which you feel could be aggravated by an increase in...

Страница 22: ...ommon crossed out wheelie bin label We accept returns of all products carrying the Insignia brand All other products are either considered outside the scope of WEEE or Insignia is not technically the...

Страница 23: ...www insigniashowers com Last Modified 07 10 2021 23...

Отзывы: