background image

 

www.insigniarange.com

 

Last Modified: 08/02/2018

 

 28 

Silicone Seal (vertical joints)

 

-

 

RubberGum (horizontal joints)

 

 

TESTING FOR WATER LEAKS

 

LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALENT TO CURE AND ENSURE THE 

SHOWER IS AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING

 

Ensure all connections are tight and sealed including the waste, body jets and steam outlet (model 

dependent) on your shower. 

We also advise to run a thin bead of silicone around the control panel.

 

Switch on the overhead shower NOT the massage jets, remember these will fire water out at you and are 
not suitable for checking leaks as they would normally only operate when a person is in front of them. DO 

NOT AIM THE HAND SHOWER AT THE JOINTS OF YOUR SHOWER AS THIS DOES NOT FALL 

UNDER 

NORMAL EVERYDAY USE

”. 

Adjust the feet to ensure the  direction of the water flows towards 

to the waste to prevent puddling.

 

Just use COLD water setting as hot will make cabin misty and condensate thus the inspection becomes 

very difficult. Now on the OUTSIDE of the shower inspect each joint, factory seal, hose, clip and jet by 

walking from one side and going around to the back and then to the other side finishing at the front. If you 

have a small leak (normally caused through insufficient sealer or air bubble on assembly, dry the area 

thoroughly and reseal.

 

Please remember the location of the water may not be exactly where the leak is as it could have run 

around to a low point. Never seal your inner fittings unless necessary, remember you will see this for the 

life of the shower! Again leave to cure and check. Once you are happy check the shower functions i.e. 

jets for back massage, foot massage and finally hand shower (model dependent) check your joints to 

these functions at the rear again. Never use the shower until 

all

 checks have been made and the installer 

is 100% happy in the knowledge no leaks are present. 

 

Important Note:

 

 

 

It is not uncommon due to temperature changes, 

 

glass seals fitted into the frame 

lower horizontal and sides can and do shrink leaving a small gap. This is normal to prevent rubbers 

perishing or opening later in your showers life. Check yours now, any slight gaps simply seal neatly with a 

thin bead of silicone. This will prevent chances of leakage both now or later in life. 

 

All good?

 

Now push your shower FROM THE BASE and NEVER THE GLASS OR FRAME into its final resting 

position.

 

Happy Showering! 

Содержание INS9005

Страница 1: ...arts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO _____...

Страница 2: ...rical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing Con...

Страница 3: ...ny years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your f...

Страница 4: ...D ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERT...

Страница 5: ...ician This product comes with 13 amp plug s fitted with an RCD unit We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current...

Страница 6: ...Electric Drill Tool Requirements None Supplied Adhesive Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints Not Supplied Supplied Not Supplie...

Страница 7: ...Y RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the final f...

Страница 8: ...s can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Note In some cases you may have more sc...

Страница 9: ...r plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a comb...

Страница 10: ...www insigniarange com Last Modified 08 02 2018 10...

Страница 11: ...de of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is blanked yet should you have a steam version you need to gently drill t...

Страница 12: ...using the M4 Nut and Bolt Ensure you run a bead of silicone between the 2 panels and apply Rubbergum under the bottom of both panels Step 2 Attach the large back panel to the left column using the M4...

Страница 13: ...d of silicone between the 2 panels and Rubbergum along the bottom of the tray Step 3 The next step is to attach the remaining column with control panel to back mir rored panel using the M4 NUT AND BOL...

Страница 14: ...www insigniarange com Last Modified 08 02 2018 14 Step 5 Attach both uprights to your top and bottom rails using the ST35 screws...

Страница 15: ...anels into place by pushing them as per the arrows in the adjacent image Making sure the edge of the glass with the rubber seal fits into the grove tightly Using the ST14 Screws and the SW9 washers se...

Страница 16: ...www insigniarange com Last Modified 08 02 2018 16 Step 7 Place and screw the upright curves into position using the ST20 screws and SW9 washers as indicated by the images...

Страница 17: ...al position Now meet the front frame to the side panels as per the image and screw together using the ST14 screws and SW9 washers We recommend Rubbergum is placed under the front frame to add to the r...

Страница 18: ...nge com Last Modified 08 02 2018 18 Step 9 Now align the roof to the glass panel and secure into position using the ST20 screws and repeat this process to fix the glass panels to the tray as indicated...

Страница 19: ...lf into your shelf brackets and secure by tightening the grub screw situated on the bottom of the bracket Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panel...

Страница 20: ...valve to the inner black tube using PTFE tape please note this only needs to be hand tight Over tightening will snap damage the inner black tube Thermostatic Probe Insert the chrome sleeve into the h...

Страница 21: ...which in turn will pull the wheels towards the track ensuring a secure a tight fit Now grease the track to ensure a smooth and long lasting operation not supplied Handles Ensuring that the inner threa...

Страница 22: ...rom then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw please ensure not to unscrew fully as thi...

Страница 23: ...Last Modified 08 02 2018 23 Connecting up the water supply Left Valve Right Valve Requires 2 x 15mm equal T Valves Not Supplied The following set up is recommended for the water supply Cold Water Sup...

Страница 24: ...iarange com Last Modified 08 02 2018 24 Electric Box Connections Connect the cables below to the corresponding devices on the shower Roof Light Speaker Antenna 12V power Supply Thermostatic probe Spea...

Страница 25: ...as shown below Follow the lights around in the order shown as this allows a consistent path around the entire roof and will leave you placing the last light next to the first light This is important...

Страница 26: ...op of the shower cabin Because of this we have a cover that simply slots over the top secured in place around the thread of the monsoon rain shower Please note this will be screwed into position once...

Страница 27: ...shower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this open...

Страница 28: ...om one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area t...

Страница 29: ...ed Other buttons will remain functional whilst in this state of lock mode Button 5 Music Press once for FM Radio and press twice for Bluetooth For tuning radio stations or connecting Bluetooth please...

Страница 30: ...tep 1 To tune your radio channels firstly press the music function button which looks like a musical note Tuning your radio channels Step 1 To connect a device via Bluetooth press the music function b...

Страница 31: ...contains many useful items such as is your parts warranty registered advice on cleaning servicing your shower cabin fault finding and many more items This is a MUST to read and not just HELP It saves...

Страница 32: ...escription SP300 Waste hose SP301 White insulated pipe SP187 Drain Hose SP234 Vertical steam generator SP308 Magnetic door seals SP310 Rear door seals SP173 SP086 SP095 SP044 SP182 SP043 3 port 3 feed...

Страница 33: ...used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All...

Отзывы: