background image

 

www.insigniarange.com

 

Last Modified: 03/04/2018

 

 02 

Contents

 

Introduction

 

Electrical Requirements

 

What

s In The Boxes?

 

Screw Pack Contents

 

Plumbing Requirements

 

Schematics 

 

Starting The Installation

 

Control Panel Connections

 

Sealing and Water Testing

 

SUN Control Panel Instructions

 

Help Book Information 

 

Part list

 

3

 

5

 

7

 

8

 

9

 

10

 

11

 

19

 

20

 

21

 

22

 

23

 

Содержание INS8721

Страница 1: ...ts Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO _...

Страница 2: ...n Electrical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Control Panel Connections Sealing and Water Testing SUN Control Panel Instr...

Страница 3: ...ny years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your f...

Страница 4: ...D ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERT...

Страница 5: ...e for electrician This product comes with 3 amp plug We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current laws and IP di...

Страница 6: ...uirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints Not Supplied Supplied Not Supplied Hardware Requirements A Hydro Massage Shower requires 2 x...

Страница 7: ...s assembled When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the u...

Страница 8: ...e obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Description Quantity SP097 Door H...

Страница 9: ...r plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a comb...

Страница 10: ...www insigniarange com Last Modified 03 04 2018 10...

Страница 11: ...ou have the need to replace anything Take the shower tub and remove all the protective wrapping and fit the waste In the side of the waste supplied in the optional fitting kit you will notice a spigot...

Страница 12: ...ghts maybe pre fitted to the front fixed glass see above to the curved rails using the ST35 screws The end with the groove is designed to sit on the tray with the flat end connecting to the roof Pleas...

Страница 13: ...018 13 Step 4 Now attach your inner uprights to your front fixed glass panels by inserting these over the thin rubber seals as shown by the arrows in the image please note that the front uprights will...

Страница 14: ...for the top and ST20 screws for the bottom There are two screws on each side please note that the front uprights will need a pilot hole drilled before screwing Step 6 Now meet the front of the shower...

Страница 15: ...s Step 8 Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of...

Страница 16: ...Note Ensure all backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories We recomm...

Страница 17: ...ve one for each end of the hose Attach the grey hose from your valve to the inner black tube using PTFE tape please note this only needs to be hand tight Over tightening will snap damage the inner bla...

Страница 18: ...ffer from the image Please refer to your outer chrome faceplate inside your Insignia shower as a reference point IF YOUR DIAL DOES NOT CORRESPOND TO THE APPROPRIATE DEVICE Turn on your water to the sh...

Страница 19: ...www insigniarange com Last Modified 03 04 2018 19 Electric Box Connections Connect the cables below to the corresponding devices on the shower Antenna Speaker Speaker Roof Light Column Lights...

Страница 20: ...om one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area t...

Страница 21: ...tton 4 5 Audio Volume Press to either turn up or down the radio volume Button 6 Padlock On Off Hold in for three to five seconds to unlock the automatically locking control panel Button 8 Power Button...

Страница 22: ...ww insigniarange com Last Modified 03 04 2018 22 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx...

Страница 23: ...el SP152 Standard shower head SP060 LED splitter cable Part Code Part Description SP300 Waste hose SP211 Transformer SP308 Magnetic door seals SP310 Rear door seals SP115 3 Port 2 feed Non Thermostati...

Страница 24: ...used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All...

Отзывы: