27
Silicone Seal (vertical joints)
-
RubberGum (horizontal joints)
TESTING FOR WATER LEAKS
LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALENT TO CURE AND
ENSURE THE SHOWER IS AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING
Ensure all connections are tight and sealed including the waste, body jets and steam outlet
(model dependent) on your shower.
Switch on the overhead shower NOT the massage jets, remember these will fire water out at
you and are not suitable for checking leaks as they would normally only operate when a person
is in front of them. DO NOT AIM THE HAND SHOWER AT THE JOINTS OF YOUR SHOWER
AS THIS DOES NOT FALL UNDER “NORMAL EVERYDAY USE”. Adjust the feet to ensure the
direction of the water flows towards to the waste to prevent puddling.
Just use COLD water setting as hot will make cabin misty and condensate thus the inspection
becomes very difficult. Now on the OUTSIDE of the shower inspect each joint, factory seal,
hose, clip and jet by walking from one side and going around to the back and then to the other
side finishing at the front. If you have a small leak (normally caused through insufficient sealer
or air bubble on assembly, dry the area thoroughly and reseal.
Please remember the location of the water may not be exactly where the leak is as it could
have run around to a low point. Never seal your inner fittings unless necessary, remember you
will see this for the life of the shower! Again leave to cure and check. Once you are happy
check the shower functions i.e. jets for back massage, foot massage and finally hand shower
(model dependent) check your joints to these functions at the rear again. Never use the shower
until
all
checks have been made and the installer is 100% happy in the knowledge no leaks are
present.
Important Note:
It is not uncommon due to temperature changes,
glass seals fitted into the
frame lower horizontal and sides can and do shrink leaving a small gap. This is normal to
prevent rubbers perishing or opening later in your showers life. Check yours now, any slight
gaps simply seal neatly with a thin bead of silicone. This will prevent chances of leakage both
now or later in life.
All good?
Now push your shower FROM THE BASE and NEVER THE GLASS OR FRAME into its final
resting position.