Control Panel Instructions

 

 

Button 5 (Mode) 

 

Whilst listening to audio you can change the volume on your control panel by pressing the 

M

” 

button. 

 

You will see the volume control represented by a number followed by 

db

” 

then use the up 

and down arrows to change your volume. 

 

Once happy with your volume leave your control panel idle for a few seconds and it will 

return to its normal screen. 

 

  

 

Button 6 (Unlock) 

 

Press to unlock the panel. 

 

Please Note: When the control panel is locked, none of the buttons will work except the 

unlock key. 

 

 

Button 7 (Down Arrow) 

 

Radio search (lower frequency)

 

music track (previous song) 

 

volume decrease. 

 

 

Button 8 (Power Button) 

 

Simply press the power button to switch on your control panel and once more to switch off 

your control panel. 

 

Once your control panel has been switched off the 03 system will automatically start and 

you will see 

“03” 

on your control panel.

 

 

 

 

To see our tutorial videos for operating this control panel

s features, 

please search for 

Insignia Showers

” 

on YouTube and find our 

SUN 

Control Panel

” 

Playlist, or you can 

click here

 

1

 

2

 

3

 

4

 

5

 

6

 

 7

 

8

 

Содержание INS8058R

Страница 1: ...Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO ___...

Страница 2: ...at care to ensure you get the best out of your build and have a shower that will last for many years to come OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK 1 Badge Ver...

Страница 3: ...rements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing SUN Control Pa...

Страница 4: ...ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERTAK...

Страница 5: ...ian This product comes with 13 amp plug s fitted with an RCD unit We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current l...

Страница 6: ...Adhesive Requirements Bacteria Resistant Sanitary Silicone for vertical joints Plumbers Mait for waste joints Not Supplied Not Supplied Hardware Requirements A Steam Shower requires 3 x 1 Metre Braide...

Страница 7: ...e use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carr...

Страница 8: ...d Insignia Screw Pack VERY IMPORTANT Have you got everything If not please contact the Insignia Support Line on 01908 226545 Remember NEVER book your tradesman until everything has arrived been checke...

Страница 9: ...plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a combi...

Страница 10: ...insigniarange com Last Modified 08 02 2018 10...

Страница 11: ...a steam version you need to gently drill this out as this item is for the steam generator drainage and will be connected in the instructions later Now please level the tray by firstly placing the tra...

Страница 12: ...ST20 screws Step 2 please note if your column has a rubber seal at the bottom take the rubber off and apply silicone inside the rubber and replace Again Once you have completed a dry run and are happ...

Страница 13: ...Once you are happy with the alignment then continue to screw the upright into place at the top and bottom using ST14 s Please note These are not pilot holed and you will need to use the DB6 1 2 1 2 1...

Страница 14: ...ST35 screws Fix the front of the top curved rail onto the upright of the front fixed angled glass Please note in order to do this you will need to slide up the front fixed panel roughly 3 inches to e...

Страница 15: ...holes to take the screws this is at a depth no deeper than 5mm Step 9 Apply silicone to specified area as shown on the diagram then take the front curved glass panel and insert into the upright Then u...

Страница 16: ...r than 5mm Step 11 Pierce through the holes using a screwdriver to show pre cut holes in the glass as indicated in the image Now using the chrome L brackets fix these to the outside of the glass panel...

Страница 17: ...o show pre cut holes in the glass as indicated in the image Now repeat the process from step 11 to secure the roof to the glass panels Step 13 Align the shower roof to your side panels and when you ar...

Страница 18: ...uated on the bottom of the bracket Accessory Installation Tri Jet Steam System Locate the three holes in the glass panel Put the Tri Jet manifold as shown through and screw the three small outlets to...

Страница 19: ...ding up and down Thermostatic Probe Insert the probe into the hole situated below the control panel roughly 6mm into the cabin and run clear silicone around the rear side of the probe Ozone o3 Unscrew...

Страница 20: ...ad Door Wheels Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are facing towards the rail then hang the top wheels on to the top inner curved rail Now on the...

Страница 21: ...exits from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw please ensure not to unscrew full...

Страница 22: ...igniarange com Last Modified 08 02 2018 22 Electric Box Connections Connect the cables below to the corresponding devices on the shower Roof Light Speaker Antenna Thermostatic probe Speaker Power Supp...

Страница 23: ...eam pod within your shower Make sure these are fitted in the correct position as they are on ly attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s cent...

Страница 24: ...s shown below Follow the lights around in the order shown as this allows a consistent path around the entire roof and will leave you placing the last light next to the first light This is important as...

Страница 25: ...insigniarange com Last Modified 08 02 2018 25 Roof cover After installing the LED light fixtures place the roof cover over the led cables as shown in the diagram...

Страница 26: ...llow children to use the steam function This function is for ADULTS ONLY Always be aware of the steam outlet pod position Never use in close proximity to the person using it Never use this shower if y...

Страница 27: ...g from one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the ar...

Страница 28: ...timer Button 3 Up Arrow Radio search higher frequency music track next song volume increase Button 4 Audio select To tune your radio channels firstly press the Audio Select button which looks like a m...

Страница 29: ...dio channels firstly press the Audio Select button which looks like a musi cal note and a Bluetooth symbol Tuning your radio channels Step1 To connect a device via Bluetooth press the music function b...

Страница 30: ...ock the panel Please Note When the control panel is locked none of the buttons will work except the unlock key Button 7 Down Arrow Radio search lower frequency music track previous song volume decreas...

Страница 31: ...insigniarange com Last Modified 08 02 2018 31 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx...

Страница 32: ...4 meters of SP270 Chromotherapy Lighting SP185 Bath Filler SP059 Air valve operation switch SP098 Chrome air jet SP052 Whirlpool pump switch Part Code Part Description SP300 Waste hose SP301 White in...

Страница 33: ...onal Ltd All images are subject to copyright Images may not be used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or...