Insignia GT8728 Скачать руководство пользователя страница 21

 

www.insigniarange.com 

Last Modified: 25/07/2013 

 21 

Need Help?

 

 

If so then simply download Insignia’s free comprehensive help and troubleshooting brochure now! 

 

Simply visit:  

www.insigniarange.co.uk/help.aspx

 

All manuals and user guides at all-guides.com

all-guides.com

Содержание GT8728

Страница 1: ...r postcode to hand before calling Email customerservice insigniarange co uk Replacements Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts ou...

Страница 2: ...What s In The Boxes Screw Pack Contents Plumbing Requirements Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing MK117 Control Panel Instructions...

Страница 3: ...erything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish OUR BADGE RATING I...

Страница 4: ...MAINS WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF A FULLY QUALIFIED ELECTRICAL COMPANY TO COMPLETE CONNECTION FROM SHOWER TO HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WAR...

Страница 5: ...hin current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version 2 Preferred Wire into isolated fused feed connecting directly to the house consume...

Страница 6: ...word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the...

Страница 7: ...arts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Descrip on Quan ty SP09...

Страница 8: ...ny circumstances Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that th...

Страница 9: ...ost cases this is blanked yet should you have a steam version you need to gently drill this out as this item is for the steam generator drainage and will be connected in the instructions later Now ple...

Страница 10: ...tep is to attach both front fixed glass panels In order to do this take the glass panel the large black edge to be situated on the entrance side to the shower and offer it up to the upright as shown b...

Страница 11: ...as shown by the arrows in the image Next screw the inner uprights to your curved rails using the ST10 screws please note that the front uprights will need a pilot hole drilled before screwing Step 5...

Страница 12: ...f the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass Once all wheels are fitted and on the rails you...

Страница 13: ...he provided white plastic foot massage retaining knobs to your glass back panel along with your chrome water outlet as shown in the above image To hang the foot massager itself to the wall push the ma...

Страница 14: ...f the probe Ozone o3 Unscrew the chrome pepper pot end and drop the white box upside down into the rear hole as shown in the image Now from the inside of the shower re attach the chrome pepper pot end...

Страница 15: ...o your outer chrome faceplate in side your Insignia shower as a reference point IF YOUR DIAL DOES NOT CORROSPOND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the wa...

Страница 16: ...Connections Phono AUX CD MP3 Thermostatic Probe RJ11 Phone Connection Radio Aerial Fan Speaker Ozone o3 Light Light 2 Earth Connect the cables below to the corresponding devices on the shower All manu...

Страница 17: ...will result in crazing of acrylic due to excessive heat generated on it Always be aware of the steam outlet pod position Never use in close proximity to the person using it Never use this shower if y...

Страница 18: ...are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this opening Drain Connect the gr...

Страница 19: ...then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal on the OUTSIDE Please r...

Страница 20: ...tween manual auto radio searching Button 9 Up Arrow Channel select up manual search up Button 10 Alarm Activate Alarm Button 11 M Set Steam Time Temperature When Radio is active this button will activ...

Страница 21: ...25 07 2013 21 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx All manuals and user guides at all...

Страница 22: ...r form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All images are registered w...

Отзывы: