background image

 

www.insigniarange.com

 

Last Modified: 23/06/2017

 

 26 

Need Help?

 

 

Then simply download the following "Help" advice booklet found at this link below. This contains many useful items such as is your

 

parts warranty

 

registered, advice

 

on 

cleaning /

 

servicing your

 

shower cabin, fault finding and many more items. This is a 

MUST

 to read and not just "HELP". It saves time

 

in nearly all

 

cases,

 

avoiding contact 

with

 

ourselves as most

 

answers are there for a ready fix! 

  

 

Simply visit:  

www.insigniarange.co.uk/help.aspx

 

Содержание GT002

Страница 1: ...s Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO __...

Страница 2: ...on Electrical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric box connections Sealing and Water Testing Control Panel Instructi...

Страница 3: ...ny years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your f...

Страница 4: ...D ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERT...

Страница 5: ...onsumer service box Remove the fitted plug and ensure the Consumer unit has capabilities to replace RCD feature if RCD is removed Always use protection against electrical surge Your shower should be t...

Страница 6: ...embled When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit a...

Страница 7: ...replacement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code D...

Страница 8: ...Blade Silicone Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill Adhesive Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum x3 Plumbers Mait for waste join...

Страница 9: ...r plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a comb...

Страница 10: ...www insigniarange com Last Modified 23 06 2017 10...

Страница 11: ...de of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is blanked yet should you have a steam version you need to gently drill t...

Страница 12: ...place in position on the tray and whilst holding in this position silicone the bottom and align the back left glass panel in the position numbered 1 on the adjacent picture and walk around into posit...

Страница 13: ...tween the two rear glass panels and screw in position using the ST20 screws Step 4 The next step is to attach the uprights to the top bottom rails using the ST35 screws wider rail with Insignia logo a...

Страница 14: ...Modified 23 06 2017 14 Step 5 Now using the ST14 screws screw in position as indicated by the image Step 6 Now use the corner uprights and place into position on either side of the frame as indicated...

Страница 15: ...ews and screw in position as indicated by the image A B Step 10 Meet the frame to the side panels as per the hand opening of your choice Note If the insignia logo is at the bottom simply peal it off a...

Страница 16: ...www insigniarange com Last Modified 23 06 2017 16 Step11 Now using the ST14 screws and screw in position as Indicated by the image...

Страница 17: ...www insigniarange com Last Modified 23 06 2017 17 Step 12 Screw down the roof to the back and side panels as well as the back walls to the shower tray using ST25 screws from the rear of the shower...

Страница 18: ...the below image Next slide the shelf into your shelf brackets and secure by tightening the grub screw situated on the bottom of the bracket Accessory Installation Please Note Ensure all grey backing...

Страница 19: ...ightening will snap damage the inner black tube Hand Shower Attach the chrome riser bar to the glass wall ensuring the water inlet is inserted through the lower large hole and hand tightened from the...

Страница 20: ...he handle on the outside of the door and secure by tightening the inner chrome knob to the protruding inner thread Wheels Fit the adjustable wheels to the top and bottom of the glass doors and ensure...

Страница 21: ...OND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome...

Страница 22: ...www insigniarange com Last Modified 23 06 2017 22 Electric Box Connections Connect the cables below to the corresponding devices on the shower Antenna Speaker Speaker Roof Light...

Страница 23: ...allow children to use the steam function This function is for ADULTS ONLY Always be aware of the steam outlet pod position Never use in close proximity to the person using it Never use this shower if...

Страница 24: ...e back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal Please rememb...

Страница 25: ...tton 4 5 Audio Volume Press to either turn up or down the radio volume Button 6 Padlock On Off Hold in for three to five seconds to unlock the automatically locking control panel Button 8 Power Button...

Страница 26: ...contains many useful items such as is your parts warranty registered advice on cleaning servicing your shower cabin fault finding and many more items This is a MUST to read and not just HELP It saves...

Страница 27: ...ter pack SP152 Standard shower head Part Code Part Description SP300 Waste hose SP211 Transformer SP187 Drain Hose SP308 Magnetic door seals SP310 Rear door seals SP115 SP193 SP091 3 Port 2 feed Non T...

Страница 28: ...used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All...

Отзывы: