Zero the  scale by pressing the 

[Zero]

  key  if  necessary.  If  a  container  is  to  be 

used, place the container on the scale and tare as discussed earlier. 

 
 

 

Place a known quantity of items on the scale. After the weight display is stable, 
enter  the  quantity  of  items  using  the  numeric  keys  followed  by  pressing  the 

[Sample/Blight] 

key.  

 

 

 

The  number  of  units  will  be  displayed  on  the 

“Total”

  display  and  the 

computed average weight will be shown on the 

“Unit Weight”

 display.  

 

 

 

As  more  items  are  added  to  the  scale,  the  weight  and  the  quantity  will 
increase.  If  the  function  “ASPL”  is  enabled  (see  section  6.1)  the  unit  weight 
will  be  automatically  recalculated  when  an  additional  mass  less  than  the 
current count is added.  

 

 

 

If the scale is not stable, the calculation will not be completed. If the weight is 
below zero, the

 “Total” 

display will show negative count. 

 
 
 Entering a known Unit Weight 

 

 

If the unit weight is already known then it is possible to enter that value using 
the keypad.   

 

 

Enter the value of the unit weight using the numeric keys followed by pressing 
the 

[U W/Units]

 key. The

 “Unit Weight” 

display will show the value as it was 

entered.  

 

 

 

The sample is then added to the scale and the weight will be displayed as well 
as the quantity, based on the unit weight. 

 
 

Содержание IBC-15

Страница 1: ...Inscale Ltd 2011 IBC SERIES Pn 700660168 RevisionC August 2011...

Страница 2: ...Inscale Ltd 2011 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place...

Страница 3: ...SPLAY 8 5 2 UNIT WEIGHT DISPLAY 8 5 3 TOTAL DISPLAY 8 6 0 KEY DESCRIPTIONS 9 7 0 WEIGHING 9 7 1 BEFORE WEIGHING 9 7 2 WEIGHING 9 7 3 ZEROING THE DISPLAY 9 7 4 TARING 10 7 5 PARTS COUNTING 10 7 6 ACCUM...

Страница 4: ...Inscale Ltd 2011 p a g e 2...

Страница 5: ...operation Four models 3kg X 0 1g 6kg X0 2g 15kg X 0 5g 30kg X 1g Large LCD with backlight 3 weighing units g kg lb Indicators for Stable zero net weight and low battery functions Stainless steel pan...

Страница 6: ...Inscale Ltd 2011 p a g e 4...

Страница 7: ...0 2g 0 5g 1g Repeatability 0 1g 0 2g 0 5g 1g Linearity 0 2g 0 4g 1g 2g Units kg g lb Stabilization time 2s 2s 2s 2s Operating temperature 0 C to 40 C 32 F to 104 F Power supply 12VDC 800mA adapter 6V...

Страница 8: ...be removed if the scale is not used for a long period of time Do not stack material on the scale when it is not in use Avoid high humidity that might cause condensation and keep away from direct cont...

Страница 9: ...ould be adjusted such that the bubble in the spirit level is in the centre of the level and the scale is supported by all four feet Attach the power supply cable to the connector on the right side of...

Страница 10: ...ator Zero Stability indicator Stable Indicators for the changed units kg g lb 5 2 UNIT WEIGHT DISPLAY This display will show the unit weight of a sample This value is either input by the user or compu...

Страница 11: ...e value from the weight and shows the results This is the net weight Entering a value using the keypad will store that as the tare value Zero Sets the zero point for all subsequent weighing It shows z...

Страница 12: ...roduct was to be added to the first one Again only the weight that is added after taring will be displayed 7 5 PARTS COUNTING In order to do parts counting it is necessary to know the average weight o...

Страница 13: ...and the quantity will increase If the function ASPL is enabled see section 6 1 the unit weight will be automatically recalculated when an additional mass less than the current count is added If the sc...

Страница 14: ...key Press the M key will return to the normal weighing 7 7 BACKLIGHT FOR LCD The backlight of the LCD can be set to be light or dark When in normal weighing mode press the Sample Blight key to change...

Страница 15: ...e to be used to determine zero tracking range of 0 5d 1d 2d 4d or Off A larger number means larger range of zero tracking and a worse repeatability the default is 1d CodE Use the keypad to set a new p...

Страница 16: ...en calibrating after 6 presses Ignore this function unless yu want to change the weighing unit during calibration Press the numeric keys to enter the calibrate mass value For kilograms and pounds ente...

Страница 17: ...Inscale Ltd 2011 p a g e 15 10 0 ERROR MESSAGE Z ERR A D counts are too high or low EEEEE Overload 9d Arrow above Lo Bat Low battery indication...

Страница 18: ...Inscale Ltd 2011 p a g e 16...

Страница 19: ...in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with...

Страница 20: ...listing of all Inscale products visit our website at www inscale co uk Copyright by inscale Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any mea...

Отзывы: