Figure 1 Wiring Diagram - Eight Lamp Sequential Operation

11

8

9

12

4

10

7

1

2

3

5

Override Sw

Master Sw

Right Amber

Right Red

Stop Arm

Left Red

Left Amber

Start Switch 

+12Volts

Flash Red Only

After Amber

Flash Red When

Door is Open

Ground

Right Amber

Right Red

Left Red

Left Amber

Master Switch

Start Switch

Door Switch

+12V

Fuse

Override Switch

+12 V

Sequence Of Operation

1. Start Switch is activated (momentary contact).
2. Amber lights start flashing (alternately).
3. Door Switch closes. Amber lights stop.
4. Red lights start flashing and stop arm is actuated.
5. Door Switch opens, red lights stop flashing and stop
    arm is retracted.
Note - Anytime Override Switch is closed red lights
start flashing immediately.

Figure 2 Wiring Diagram - Eight Lamp Non-Sequential Operation

Right Amber

Right Red

Left Red

Left Amber

Master Switch

Start Switch

Door Switch

+12V

Fuse

Override Switch

+12 V

+12 V

Sequence Of Operation

1. Start Switch is activated (momentary contact).
2. Amber lights start flashing (alternately).
3. Door Switch closes.
4. Amber lights stop and red lights start flashing.
5. Door Switch opens, red lights stop flashing.
Note - Anytime the Door Switch or Override Switch
is closed red lights start flashing immediately.

Figure 3 Wiring Diagram - Four Lamp Sequential Operation

Right Front

Right Rear

Left Front

Left Rear

Master Switch

Start Switch

+12V

Fuse

Override Switch

+12 V

Sequence Of Operation

1. Start Switch is activated (momentary contact).
2. Red lights start flashing (alternately).
3. Door Switch closes.
4. Stop Arm is actuated and red lights continue to flash.
5. Door Switch opens, red lights stop flashing and 
Stop Arm is retracted.
Note - Anytime Override Switch is closed red lights
start flashing immediately but Stop Arm only actuates
when Door Switch is actuated.

Specifications

Operating Voltage:

8 to 16 Volts DC

Output Current Rating
   Lamps (Pins 7, 9, 10, & 12):

16 amps

   Stop Arm (Pin 4):

3 amps

Operating Temperature:

-40 deg C to +85 deg C

Storage Temperature:

-50 deg C to +85 deg C

Mechanical Drawing

11

8

9

12

4

10

7

1

2

3

5

11

8

9

12

4

10

7

1

2

3

5

+12 V

+12 V

Fuse

Fuse

Fuse

All dimensions in inches.

1.75

2.30

0.50

1.25

1.80

Top View

View looking into Amp
Multilock 070 connector
on flasher unit.

SBF94

Master Sw

6

6

6

1

2

3

4

5

6

7

8

9

10

11

12

Connector Pin Layout

View of Connector Side

Side View

0.31

Stop

Arm

Stop

Arm

Override Sw

Master Sw

Right Amber

Right Red

Stop Arm

Left Red

Left Amber

Start Switch 

+12Volts

Flash Red Only

After Amber

Flash Red When

Door is Open

Ground

SBF94

Master Sw

Override Sw

Master Sw

Right Amber

Right Red

Stop Arm

Left Red

Left Amber

Start Switch 

+12Volts

Flash Red Only

After Amber

Flash Red When

Door is Open

Ground

SBF94

Master Sw

Door Switch

Stop

Arm

Отзывы: