INOXPA PHARMAVALVE Скачать руководство пользователя страница 4

 

 

ED. 2009/09 / 

 

The valve contains parts operating with linear movement. Do not place your hands or fingers in the 
valve shut-off area. This may cause serious injuries. 

 
1.4.3.  

 

During maintenance 

 

 

The 

Technical Specifications

 of Chapter 8 should always be observed. 

 
NEVER disassemble the valve until the pipes have been drained. Bear in mind that the liquid in the 
pipe may be dangerous or extremely hot. Consult the regulations in effect in each country in these 
cases. 
 
Do not leave parts loose on the floor. 

 

 

All electrical work should be carried out by authorized personnel. 

 
1.4.4.  

 

In compliance with the instructions. 

Any non-compliance with the instructions may result in a risk for the operators, the environment and the machine, and may 
result in the loss of your right to claim damages. 
This non-compliance may result in the following risks: 

 

Failure of important functions of the machines/plant. 

 

Failure of specific maintenance and repair procedures. 

 

Possibility of electric, mechanical and chemical risks. 

 

Danger to the environment due to the release of harmful substances. 

 

1.5. 

 

GUARANTEE 

Any guarantee will be negated immediately and, as a matter of law and in addition, we will require compensation for any claims 
of civil liability presented by third parties, in the instance of: 
 

 

The installation and maintenance work has not been carried out according to the instructions of this manual. 

 

The repairs are not carried out by our personnel or have been carried out without our written authorization. 

 

The parts used are not INOXPA genuine parts. 

 

Modifications have been carried out on our materials without written authorization. 

 

The material has been badly used, incorrectly used, or used with negligence or has not been used according to the 
indications and intended use specified in this manual. 

 
The general conditions of delivery already in your possession are also applicable. 
 

 

No change can be made to the equipment without prior discussion with the manufacturer. For your 
safety, please use original spare parts and accessories.  
The use of other parts will exempt the manufacturer from any liability. 
 
The service terms can only be changed with prior written authorization from INOXPA. 

 
 

 
Please do not hesitate to contact us in case of doubts or if more complete explanations are required on specific data 
(adjustments, assembly, disassembly, etc.). 

Содержание PHARMAVALVE

Страница 1: ...VIC STRUC ARMAV INOXPA lers 54 A 17820 Ba Girona S 34 972 34 972 inoxpa www inoxp E AND CTIONS AVALVE S A Aptdo 17 anyoles Spain 57 52 0 57 55 0 inoxpa co pa com ORIGI D MAIN S E 4 00 02 om INAL MAN N...

Страница 2: ...actice determined according to Article 3 Section 1 3 a first paragraph annex II table 6 This material should not have the CE marking Diameter DN 25 X or DN 100 Equipment category Category I determined...

Страница 3: ...loads Danger to the correct operation of the equipment Commitment to safety at the workplace Protective goggles requirement 1 4 GENERAL SAFETY INSTRUCTIONS Read the instruction manual carefully befor...

Страница 4: ...1 5 GUARANTEE Any guarantee will be negated immediately and as a matter of law and in addition we will require compensation for any claims of civil liability presented by third parties in the instanc...

Страница 5: ...cation 8 3 6 Flow direction 8 3 7 Assembly 8 3 8 Inspecting and checking 9 3 9 Welding 9 3 10 Air connection to actuator 10 4 Start up 4 1 Start up 11 4 2 Operation 11 5 Operating problems Causes and...

Страница 6: ...from the valve or parts Inspect the valve or its constituent parts for possible damage caused during transport Avoid any possible damage to the valve and its components 3 3 STORAGE If the valve and or...

Страница 7: ...ATIC 5 TANK BOTTOM NO PNEUMATIC 6 A A PNEUMATIC 7 TANK BOTTOM A A PNEUMATIC CASING DESIGN 0 L CASING O D ASME 1 T CASING O D ASME 2 45o OUTLET O D ASME CASING MATERIAL 06 AISI 316L DIAPHRAGM MATERIAL...

Страница 8: ...rection of closure In T type bodies the normal direction is shown in figure c as it minimises pressure losses and dead zones T type casings are NOT 3 way valves they act as a divider when the valve is...

Страница 9: ...lding work can only be carried out by persons qualified trained and equipped with the necessary means to carry out this work Disassemble the valve before starting the welding work 3 9 1 PHARMAVALVE Bu...

Страница 10: ...low intensity High intensity may deform the valve Continue welding until the body is completely welded Leave to cool gradually Cool by air only Turn over the tank base and weld from the inside Leave...

Страница 11: ...e Chapter 8 Technical Specifications Bear in mind the quality of the compressed air in accordance with the specifications described in chapter 8 Technical Specifications Operate the valve 4 2 OPERATIO...

Страница 12: ...ibration Replace the diaphragm with one of a different material and more appropriate to the product Tighten any loose components Clean frequently In actuators NO and A A reduce the air pressure Backpr...

Страница 13: ...g maintenance Danger of burns 6 2 1 Diaphragm Maintenance REPLACING THE DIAPHRAGM Preventive maintenance Replace after twelve 12 months In general the diaphragm must be inspected every 50 hours of ste...

Страница 14: ...at 70 C 150 F 1 Kg NaOH 100 l of water cleaning solution or 2 2 l NaOH at 33 100 l of water cleaning solution b Acid solution 0 5 by weight of nitric acid HNO3 at 70 C 150 F 0 7 litres HNO3 at 53 100...

Страница 15: ...ft as appropriate for type A or B 2 Place the actuator 10 in the open valve position Connect the body 01 to the actuator 10 using the clamp 34 The type A diaphragm press on is standard for Silicone an...

Страница 16: ...he actuator 10 in order to set the diaphragm 05 in the open position NC valve only Connect the body 01 to the actuator 10 by tightening the clamp 34 Disconnect the compressed air from the actuator 1 s...

Страница 17: ...h DIN ISO 8573 1 o Solid particle content Class 3 quality Max particle size 5 microns Max particle density 5 mg m3 o Water content Class 4 quality max dew point 2 o C If the valve is operating at high...

Страница 18: ...18 ED 2009 09 8 1 VALVE DIMENSIONS 10 310 32 0010...

Страница 19: ...eumatic Actuator H 42 77 5 94 5 I 60 69 90 Bodies J TC50 5 TC77 5 TC77 5 k 82 124 124 L 41 62 62 M 19 5 32 37 5 N 36 5 61 2 67 2 O 50 79 100 P 47 104 120 Q 28 5 52 R 60 95 5 121 7 T 94 208 240 U 35 67...

Страница 20: ...1 01B Nut support AISI 316L 1 04 Handle AISI 316 1 05 Diaphragm 1 08 Diaphragm shaft AISI 316 1 17A Support bushing AISI 316 1 17B Guide bushing PTFE 1 17I Bearing bushing AISI 316 1 20B O ring FPM 1...

Страница 21: ...06 Spring AISI 302 5 08 Piston shaft AISI 316L 1 08A Diaphragm shaft AISI 316L 1 11 Spring guide POM 1 17 Guide bushing PTFE 1 18C R 1 8 straight connector 1 18D R 1 8 Silencer 1 20A O ring FPM 1 20F...

Страница 22: ...NOTES...

Страница 23: ...NOT TES...

Страница 24: ...X GLEIZE BASSE GOULAINE WAMBRECHIES Tel 33 474627100 Tel 33 228010172 Tel 33 320631000 Fax 33 474627101 Fax 33 228010173 Fax 33 320631001 e mail inoxpa fr inoxpa com e mail inoxpa fr inoxpa com e mail...

Отзывы: