7. Maintenance
17
7.3.2.
Automatic SIP (Sterilization-in-Place)
Sterilization with steam is applied to all equipment including the pigging.
Do NOT start the equipment during the sterilization with steam.
The parts/Materials will not be damaged if the indications specified in this manual are
observed.
No cold fluid can enter the equipment until the temperature of the equipment is lower than
60°C (140°F).
Maximum conditions during the SIP process with steam or superheated water:
a) Max. temperature:
140°C / 284°F
b) Max. time:
30 min
c) Cooling:
Sterile air or inert gas
d) Materials:
EPDM (HNBR and FPM materials are not recommended)
7.4.
ASSEMBLY AND DISASSEMBLY
Proceed with caution. Personal injury can occur.
Always disconnect the compressed air before starting to disassemble the valve.
Never disassemble the valve clamps directly without reading the instructions carefully, since
the actuator contains a spring inside it with an applied load.
Valve and/or actuator assembly and disassembly should only be done by qualified persons.