Motor overload
Insufficient agitation
Vibrations and noise
Leaks
PROBABLE CAUSES
SOLUTIONS
•
•
Viscosity of the liquid too high
Reduce the viscosity, e.g. by heating
the liquid
•
High density
Increase motor power
•
Tank too big for the chosen agitator
Check with the technical department
•
Wrong direction of rotation
Change direction of rotation
•
Agitator speed too low
Increase the speed
•
Liquid level insufficient or none
Check liquid level in the tank
•
Shaft bended
Replace the shaft
•
Critical speed
Check with the technical department
•
Worn bearings
Replace the bearings agitator
•
Lip seal worn or damaged
If the lip seal is worn, replace it.
If the lip seal is damaged, consult the
technical department.