INOXPA ASPIR A-150 Скачать руководство пользователя страница 16

Maintenance 

 

   

 

16 

 

INOXPA S.A.U.

 

· 01.400.30.09EN · (0) 2021/04 

8.7.  DISASSEMBLY AND ASSEMBLY OF THE PUMP 

The  assembly  and  disassembly  of  the  pumps  should  be  done  by  qualified  personnel.  Make  sure  that  the 
personnel read carefully this instruction manual and, in particular, those instructions which refer to the work they 
will perform. 

 

 

Incorrect assembly or disassembly may cause damage in the pump’s operation and  lead to  high 
repair costs and a long period of down time. 

INOXPA  is  not  responsible  for  accidents  or  damages  cause  by  a  failure  to  comply  with  the 
instructions in this manual. 

 

Preparation

 

Provide  for  a  clean  working  environment  so  some  parts,  including  the  mechanical  seal,  require  very  careful 
handling and others have close tolerances. 

Check that the parts which are  used are not damaged during transport.  When doing this, you  need to  inspect 
the adjustment edge, the butted faces, the tight fit, burrs, etc. 

After each disassembly, carefully clean the parts and check for any damage. Replace all damaged parts. 

 

Tools 

Use the proper tools for assembly and disassembly operations. Use them correctly. 

 

Cleaning 

Before disassembling the pump, clean it outside and inside. 

 

 

NEVER clean the pump by hand when it is running. 

 

 

8.7.1. Disassembly of the pump and single mechanical seal 

 

1.  Remove the clamping ring (15) and disassemble the 

disassemble the discharge casing (01A). 

2.  Check the condition of the O-ring (80) on the suction 

casing and replace if damaged 

3.  Ensure that the O-ring is placed is not twisted during 

the assembly. 

4.  Remove  the  diffuser  (16).  May  be  that  when  the 

discharge  casing  (01A)  is  extracted,  the  diffuser 
leaves together with it. 

5.  Loosen  the  countersunk  screw  (50)  that  fixes  the 

impeller. 

6.  Remove  the  washer  (35)  and  the  impeller  (02).  If  is 

necessary  use  an  extractor  at  impeller  threaded 
holes. 

7.  Remove the screws (50A) and remove the protector 

(47A). 

8.  Remove  the  screws  (52B)  and  the  suction  casing 

(01). 

9.  Manually remove the stationary part of the seal (08) 

which is located in the suction casing (01). 

10. The  rotating  part  is  located  free  on  the  shaft  (05). 

Slide it by the shaft. 

11. Check  the  sealing  surfaces  and  O-rings  from  the 

mechanical seal (08) are not damaged. 

 

 

 

 

0

1

.4

0

0

.3

2

.0

0

1

2

 

0

1

.4

0

0

.3

2

.0

0

1

1

 

ATTENTION 

Содержание ASPIR A-150

Страница 1: ...INSTALLATION SERVICE AND MAINTENANCE INSTRUCTIONS SIDE CHANNEL PUMP ASPIR Original Instructions 01 400 30 09EN 0 2021 04 01 400 32 0005...

Страница 2: ...From serial number IXXXXXX to IXXXXXX 1 XXXXXXXXXIIN to XXXXXXXXXIIN 1 Fulfills all the relevant provisions of the following directive Machinery Directive 2006 42 CE Regulation EC n 1935 2004 Applica...

Страница 3: ...l seal with quench 9 5 7 Electrical installation 10 6 Start up 6 1 Checks before starting the pump 11 6 2 Checks when starting the pump 11 7 Troubleshooting 8 Maintenance 8 1 General considerations 14...

Страница 4: ...ns failure of specific maintenance and repair procedures possible electrical mechanical and chemical hazards risk to the environment due to the type of substances released 2 3 WARRANTY The conditions...

Страница 5: ...s can the specified limit values be exceeded NEVER touch the pump or the pipework during operation if the pump is being used for transferring hot liquids or during cleaning The pump contains moving pa...

Страница 6: ...gh the discharge casing 4 3 APPLICATION ASPIR pump is a sanitary side channel self priming pump suitable for use in the food processing pharmaceutical and chemical industries It is specially designed...

Страница 7: ...uctions manual instructions and service manual of the motor1 Unpack the pump and check the following The suction and discharge connections of the pump removing any rest of packaging materials The pump...

Страница 8: ...Specifications to consult dimensions and weights During the transport disassembly or assembly of the pump there is a risk of loss of stability and that the pump could fall down and cause damages to th...

Страница 9: ...ligned with the pipework and have a diameter similar to that of the pump connections Place the pump as close as possible to the suction tank and whenever possible below the liquid level or even below...

Страница 10: ...age Before handling the pump make sure that the motor is stopped Connect the motor in accordance with the instructions supplied by the motor manufacturer in accordance with the current national legisl...

Страница 11: ...y pass option when it suction from a level below of the pump level the by pass will be closed why it will not suction 6 2 CHECKS WHEN STARTING THE PUMP Check that the pump is not making any strange no...

Страница 12: ...04 Use special protection when the sound pressure in the operation area exceeds 85 dB A If the pump has not an incorporated a pressure by pass you should mount a relief valve or any other device that...

Страница 13: ...suction line Pump not drained Drain or fill Cavitation Increase suction pressure Air is suctioned by the pump Check the suction pipe and all its connections Clogged suction pipe Check the suction pip...

Страница 14: ...structions in the chapter 8 7 Disassembly and assembly of the pump 8 3 MAINTENANCE OF THE SEALS SEALS REPLACEMENT Preventive maintenance Replace after twelve 12 months We also recommend replacing the...

Страница 15: ...tic cleaning process is not provided proceed to disassemble the pump as indicated in the chapter 8 7 Disassembly and assembly of the pump Check the concentration of the cleaning solutions Incorrect co...

Страница 16: ...maged parts Tools Use the proper tools for assembly and disassembly operations Use them correctly Cleaning Before disassembling the pump clean it outside and inside NEVER clean the pump by hand when i...

Страница 17: ...en installing the new seal use soapy water when fitting the different parts and gaskets to allow them to slide better Apply to the stationary as well as the rotating parts 8 7 3 Motor change 1 Firstly...

Страница 18: ...the shaft with a new one Fix the shaft according the table of chapter 8 6 1 Disassembly of the pump and single mechanical seal 5 Assembly the suction cover 01 carefully to avoid damaging the lip seal...

Страница 19: ...nical seal Type of seal single inside seal Material of stationary part graphite C standard silicon carbide SiC Material of rotating part silicon carbide SiC standard Seal material EPDM standard FPM Wa...

Страница 20: ...kg IEC 80 100 112 132 160 kW 0 75 2 2 3 4 5 5 7 5 11 15 A 50 22 A 80 48 53 59 A 150 58 75 85 A 200 143 166 9 3 DIMENSIONS WITH WHROUD AND LEGS Pump type Motor Dimensions mm IEC A B C A 50 80 290 529 3...

Страница 21: ...1 9 4 DIMENSIONS WITHOUT WHROUD AND WITHOUT LEGS Pump type Motor Dimensions mm IEC kW A B C A 50 80 200 422 220 A 80 100 261 568 265 112 261 590 291 A 150 112 4 265 590 291 132 5 5 300 640 332 7 5 300...

Страница 22: ...Technical Specifications 22 INOXPA S A U 01 400 30 09EN 0 2021 04 9 5 EXPLODED DRAWING OF ASPIR PUMP 01 400 32 0015...

Страница 23: ...1 08A Mechanical seal stationary part 1 14 Shroud 1 1 4301 AISI 304 15 Clamp body 1 1 4301 AISI 304 16 Diffuser 1 CF3M 35 Fixation impeller washer 1 1 4404 AISI 316L 47A Lantern protection 2 PETP 50...

Страница 24: ...01 400 30 09EN 0 2021 04 9 7 MECHANICAL SEAL WITH QUENCH Position Description Quantity Material 05A Shaft for quench 1 1 4404 AISI 316L 88 Lip seal 1 92 Quick connector for tube D 8 2 1 4404 AISI 316...

Страница 25: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Страница 26: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Страница 27: ..._____________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________...

Страница 28: ...nyoles Spain Tel 34 972 575 200 Fax 34 972 575 502 How to contact INOXPA S A U Contact details for all countries are Continually updated on our website Please visit www inoxpa com to access the inform...

Отзывы: