Once the TapWatch gateway is functional, the LEDs will function as follows:

• Green: Blinks when powering up; solid when power up is complete.
• Orange: Blinks while establishing an IP connection; solid when IP 

connected.

• Red: Blinks upon message receipt from any transmitter.

3 Tips and Notes

3.1 Installation Notes

• These products are designed to be maintained by professional 

technicians.

• Products are tested for indoor use.
• Inovonics recommends registering and testing end devices prior to 

installation, using a floor plan or something similar to indicate 

installation locations. Consider marking or applying descriptive labels 

to the end device cases to ensure proper installation. Conduct a site 

survey with an Inovonics survey kit prior to installation to assist with 

RF gateway, repeater and end device placement.

• To resolve connectivity issues, check for loose/disconnected cabling, 

ensure power to Ethernet routers and/or switches, and connect a 

laptop to the Ethernet cable attached to the TapWatch gateway’s 

RJ45 port and attempt to open a web site. If you are still unable to 

establish an Internet connection, contact a facility IT representative.

• Metal will reduce radio frequency (RF) range. Mount the TapWatch 

gateway in a location removed from metal, including duct work, wire 

mesh screens, IT closets, metal boxes, and etc. For additional 

information, see the "EchoStream Device Installation 

Recommendation" tech note at www.inovonics.com.

• The EchoStream system should be tested regularly to ensure 

operation.

4 Questions

If you have any problems with this procedure, contact Inovonics technical 

services:

• E-mail: [email protected].
• Phone: (800) 782-2709; (303) 939-9336.

5 Specification

Dimensions: 

9.556” x 6.65” x 1.208” (242.72 mm x 168.91 mm x 30.68 

mm).

Power requirements: 

Line power: The Inovonics ACC610 transformer, or 

a 12-14V AC intrinsically safe power supply capable of supplying at least 

20VA, or a 12-15V DC power supply capable of supplying at least 20VA; 

POE: IEEE 802.3af-2003 compliant.

Router requirements:  

The router must assign addresses via DHCP; the 

DHCP lease of the router must be set to a non-zero and non-infinite value, 

and should be set to a value greater than 30 seconds; The router must 

allow outbound connections on the following ports: DNS (53), HTTPS 

(443), NTP (123).

Ethernet: 

10/100BASE-T, DHCP.

Operating frequencies: 

EchoStream: 902 - 928 MHz North America, 915 - 

928 MHz Australia, 921 - 928 MHz New Zealand; Wi-Fi® and Bluetooth®: 

2.4GHz to 2.5 GHz.

Operating environment: 

Temperature: 32°F to 140°F; humidity: Up to 

90% non-condensing.

Regulatory compliance: 

FCC, Industry Canada, RoHS.

6 Regulatory Compliance

6.1 Television and Radio Interference

This equipment has been tested and found to comply with the limits for a 

Class B digital device, pursuant to Part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference 

in a residential installation. This equipment generates, uses and can 

radiate radio frequency energy and, if not installed and used in accordance 

with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not 

occur in a particular installation.  If this equipment does cause harmful 

interference to radio or television reception, which can be determined by 

turning the equipment off and on, the user is encouraged to try to correct 

the interference by one or more of the following measures:

• Increase the separation between the equipment and receiver.
• Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible 

for compliance could void the user's authority to operate the equipment.

6.2 FCC Part 15 and Innovation, Science and Economic 

Development Canada (ISED) Compliance

This device complies with part 15 of the FCC Rules, and ISED license-

exempt RSS standard(s). Operation is subject to the following two 

conditions: (1) this device may not cause interference, and (2) this device 

must accept any interference that may cause undesired operation of the 

device.
Le présent appareil est conforme aux CNR Innovation, Sciences et 

Développement économique Canada applicables aux appareils radio 

exempts de licence. L'exploitation est autorisée aux deux conditions 

suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur 

de l'appareil doit accepter tout brouillage radioélectrique subi, même si le 

brouillage est susceptible d'en compromettre le fonctionnement.

6.3 Radiation Exposure Limits

FCC

This equipment complies with FCC radiation exposure limits set forth for an 

uncontrolled environment. In order to avoid the possibility of exceeding the 

FCC radio frequency exposure limits, human proximity to the antenna shall 

not be less than 20 cm during normal operation and must not be co-located 

or operating in conjunction with any other antenna or transmitter.

ISED

This equipment complies with ISED RSS-102 radiation exposure limits set 

forth for an uncontrolled environment. This transmitter must be installed to 

provide a separation distance of at least 20 cm from all persons and must 

not be co-located or operating in conjunction with any other antenna or 

transmitter.
Cet équipement est conforme avec ISED RSS-102 des limites d'exposition 

aux rayonnements définies pour un environnement non contrôlé. Cet 

émetteur doit être installé à au moins 20 cm de toute personne et ne doit 

pas être colocalisé ou fonctionner en association avec une autre antenne 

ou émetteur.

(800) 782-2709; (303) 939-9336

[email protected]

www.inovonics.com

For product and installation videos visit us at 

www.inovonics.com/videos or use the QR 

code below.

Содержание TapWatch Gateway EN7580

Страница 1: ...back of the housing Record the eight character alphanumeric authorization code from the label on the lower right hand portion of the printed circuit board just above the Inovonics logo 3 Use a Phillips screwdriver to open the TapWatch gateway housing 4 Connect power to the TapWatch gateway routing cabling through the TapWatch gateway housing knockout If using line power connect a power supply to t...

Страница 2: ...ect Australia or New Zealand or remove it for North America c If you have changed the frequency band press the reset button to complete configuration 8 If deploying the TapWatch gateway on a site with Frequency Agile FA hardware you will need to connect an FA403 receiver to the TapWatch gateway if not deploying the TapWatch gateway on a site with FA hardware skip to step 9 You will wire the FA403 ...

Страница 3: ... a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee...

Страница 4: ...ure limits for general population uncontrolled expose the antenna s used for this transmitter must be installed to provide a separation distance of at least 29mm from all persons and operating in conjunction with any other antenna or transmitter except in accordance with FCC multi transmitter product procedures 7 Open Source Software Notice and Information To obtain the source code under GPL LGPL ...

Отзывы: