4.29.22 357-00061-01 Rev A © Inovonics, 2022 - www.inovonics.com 

2

a. 

Ensure the frequency band is set for your geographic area.

b. 

If the frequency band is not set for your geographic area, place a 

selection jumper on the appropriate frequency band selection pins to 

select Australia or New Zealand, or remove it for North America.

c. 

If you have changed the frequency band, press the reset button to 

complete configuration.

 Figure 4  

Frequency band selection pins

Note: 

Steps 8 through 12 are required for EchoStream directed networking 

support.

8.

If using an existing EN7380 configuration file, open the configuration file 

and proceed to step 11; if using a new configuration file:

a. 

Press the senior living gateway’s reset button.

b. 

Wait for the green LED to flash.

c. 

Insert a USB flash drive into either of the senior living gateway's USB 

ports.

d. 

When the red LED is solidly lit, remove the USB drive.

e. 

Insert the USB drive into a PC.

 Figure 5  

Reset button, LEDs and USB ports

9.

On your PC, open the configuration file from the USB drive. 

• It will be named en7380-XX-config-YYYYMMDD-HHMMSS.yaml, 

where XX is the last two hex digits of the Ethernet MAC address, as 

shown on the label on the back of the housing, and YYYYMMDD-

HHMMSS is the current date and time.

10.

Enter the configuration information into the .yaml file:

• Configure the network connectivity as desired. By default, only 

Ethernet is enabled with DHCP; WiFi is disabled. 

• Configure the senior living gateway for a directed network by setting 

the NID value in the .yaml file. The keyword NID and value is required 

in the radio section of the configuration file.

Note: 

When using the senior living gateway with a directed network, the 

EN6040 network coordinator needs to remain powered at all times to 

ensure continuous operation.

11.

Save the configuration file onto the USB drive as 

en7380-config.yaml.

12.

Load the configuration file onto the senior living gateway:

a. 

Safely eject the USB drive from the PC.

b. 

Press the senior living gateway’s reset button.

c. 

Wait for the green LED to flash.

d. 

Insert the USB flash drive into either of the senior living gateway's 

USB ports.

e. 

When the red LED is solidly lit, indicating the gateway has finished 

processing the configuration file, remove the USB drive.

Note: 

If the red LED is not solidly lit, the yaml file did not load. Please 

check formatting, ensure you are using N+ or a similar yaml editor 

and use a yaml validator such as yamllint.com.

13.

Use a Phillips screwdriver to close the senior living gateway housing.

Once the senior living gateway is functional and all transmitter TXIDs have 

been registered, the LEDs will function as follows:

• Green: Blinks when powering up; solid when power up is complete.
• Orange: Blinks while establishing an IP connection; solid when IP 

connected.

• Red: Blinks upon message receipt from any transmitter.

3 Tips and Notes

3.1 Installation Notes

• These products are designed to be maintained by professional 

technicians.

• Products are tested for indoor use.
• Inovonics recommends registering and testing end devices prior to 

installation, using a floor plan or something similar to indicate 

installation locations. Consider marking or applying descriptive labels 

to the end device cases to ensure proper installation. Conduct a site 

survey with an Inovonics survey kit prior to installation to assist with 

RF gateway, repeater and end device placement.

• Use a brand name USB flash drive with a FAT32 (vfat) filesystem for 

configuration.

• The senior living gateway configuration file is YAML formatted. See 

yaml.org for details.

• If using line power, keep cable length to less than 10 feet to minimize 

noise pickup.

• To resolve connectivity issues, check for loose/disconnected cabling, 

ensure power to Ethernet routers and/or switches, and connect a 

laptop to the Ethernet cable attached to the senior living gateway’s 

RJ45 port and attempt to open a web site. If you are still unable to 

establish an Internet connection, contact a facility IT representative.

• Metal will reduce radio frequency (RF) range. Mount the senior living 

gateway in a location removed from metal, including duct work, wire 

mesh screens, IT closets, metal boxes, and etc. For additional 

information, see the "EchoStream Device Installation 

Recommendation" tech note at www.inovonics.com.

• The EchoStream system should be tested regularly to ensure 

operation. To test, place the system in test mode, activate an end 

device, and ensure an appropriate response.

4 Specification

Dimensions: 9.556” x 6.65” x 1.208” (243 mm x 169 mm x 31 mm).

Power requirements: Line power: The Inovonics ACC610 transformer, or a 

12-14V AC intrinsically safe power supply capable of supplying at least 

16W, or a 12-15V DC power supply capable of supplying at least 15W; 

POE: IEEE 802.3af-2003 compliant.

Ethernet: 10/100 BASE-T, DHCP, static IP.

WiFi: 802.11b/g/n, 2.4GHz, WPA/2-Personal, DHCP, static IP.

Operating frequencies: EchoStream: 902 - 928 MHz North America, 915 - 

928 MHz Australia, 921 - 928 MHz New Zealand; Wi-Fi® and Bluetooth®: 

2.400 GHz to 2.485 GHz.

Operating environment: Temperature: 32°F to 140°F; humidity: Up to 90% 

non-condensing.

Regulatory certifications: FCC, RoHS, RCM, ISED.

Note: 

Specifications and data are subject to change without notice.

Note: 

Inovonics supports recycling and reuse whenever possible. Please 

recycle these parts using a certified electronics recycler.