Inovonics EN1262HT Скачать руководство пользователя страница 2

12.9.21 357-00056-01 Rev A © Inovonics, 2021 - www.inovonics.com 

2

5.

Use the included mounting screws to mount the EN1262HT.

• To mount on the wall, see Figure 4.
• To mount in a corner, see Figure 5.

 Figure 4  

Wall mount configuration

 Figure 5  

Corner mount configuration

6.

Install the battery per Figure 6.

 Figure 6  

Install the battery

Note: 

When disposing of this device or depleted batteries, please do so in 

accordance with federal, state and local regulations.

2.3 Select Pulse Count

The pulse count options provides control for difficult operating 

environments. Automatic pulse count is recommended for reliable 

operation in environments subject to temperature fluctuation that can cause 

false alarms. The single pulse count mode is more sensitive to minor 

temperature variations, and should be used in sites where variant heat 

sources will not cause alarms. Automatic pulse count is the factory default 

because it allows more reliable operation in environments subject to 

temperature fluctuation. To select pulse count:

1.

Press the tamper button five times within three seconds.

 Figure 7  

Press the tamper button

2.

Wait for the green LED to blink five times, then:

• Press the tamper button one time within three seconds to select single 

pulse count.