12.9.21 357-00056-01 Rev A © Inovonics, 2021 - www.inovonics.com
2
5.
Use the included mounting screws to mount the EN1262HT.
• To mount on the wall, see Figure 4.
• To mount in a corner, see Figure 5.
Figure 4
Wall mount configuration
Figure 5
Corner mount configuration
6.
Install the battery per Figure 6.
Figure 6
Install the battery
Note:
When disposing of this device or depleted batteries, please do so in
accordance with federal, state and local regulations.
2.3 Select Pulse Count
The pulse count options provides control for difficult operating
environments. Automatic pulse count is recommended for reliable
operation in environments subject to temperature fluctuation that can cause
false alarms. The single pulse count mode is more sensitive to minor
temperature variations, and should be used in sites where variant heat
sources will not cause alarms. Automatic pulse count is the factory default
because it allows more reliable operation in environments subject to
temperature fluctuation. To select pulse count:
1.
Press the tamper button five times within three seconds.
Figure 7
Press the tamper button
2.
Wait for the green LED to blink five times, then:
• Press the tamper button one time within three seconds to select single
pulse count.