Inovonics EN1221S-60 Скачать руководство пользователя страница 4

11.10.20 357-06536-01 Rev A © Inovonics, 2020 - www.inovonics.com 

4

8 Device Indicators

9 Water Exposure

UL has evaluated the EN1221S-60 series pendants to meet the water 

spray and submersion tests required under UL 2560, section 38. 
In addition, these pendants meet IP67 certification standards for dust and 

water ingress protection, ensuring that:

• Ingress of dust particles does not interfere with the satisfactory 

operation of the device.

• There is no harmful effect to the device caused by:

-  Submersion up to three feet (one meter) for less than or equal to 

30 minutes.

Note: 

IP67 certification was performed by an independent laboratory not 

affiliated with UL.

10 End User Recommendations

The pendant transmitter housing is waterproof up to the IP67 standard 

when the battery door is properly seated and in the locked position. The 

product is designed for incidental/momentary submersion in water, but not 

for extended submersion. As such, we offer the following recommendations 

to the end user:

* The pendant is able to successfully transmit an alarm or check-in
message when exposed intermittently to water in a shower setting.
However, when the pendant is fully submerged, the water absorbs the radio
signal such that messages may not be reliably detected by the receiver.

11 Specifications

Dimensions: 1.6" x 1.6" x 0.5" (4 x 4 x 1.25 cm).
Weight: 0.6 oz (17 g) with battery inserted.
Operating temperature: 32 to 140°F (0 to 60°C).
Operating environment: Waterproof to IP67 standard.
Estimated battery life: One year (assuming five alarm activations per day 

and alarm clearance within ten minutes of alarm activation).
Battery type: Panasonic CR2032.
Power requirement: 3VDC, 14.5µA.
Storage requirement: Ambient conditions of 69 to 73°F (20.5 to 22.8°C).
Compliance for EN1221S-60AN, EN1221S-60ZN, EN1221S-60AW and 

EN1221S-60ZW: AS/NZS 4268:2012 Radio Systems Equipment - Short 

Range Devices.
UL certification for EN1221S-60N and EN1221S-60W: UL 2560 (see 

conditions below).

Note: 

For UL 2560 installations, Inovonics repeaters must have 20 minute 

check-in times. Inovonics transmitters must have a minimum of 60 minute 

check-in times.

Note: 

In a UL 2560 installation, the EN1221S-60 series pendants may be 

used with completed emergency call systems for assisted living and 

independent living facilities.

For UL 2560 certified system installations, the following Inovonics 

EchoStream devices are approved for installation within maximum system 

configuration limits defined in section 1.2 of this document:

• EN6080 area control gateway or EN6040-T network coordinator with 

transformer.

• EN5040-20T high power repeater.
• End devices (transmitters) with a minimum 60-minute check-in 

interval, as follows: 

-  Fundamental devices which are subject to UL 2560 certification 

(pendant transmitters and OEM products using the Inovonics RF 

module).

-  Supplemental devices which are not subject to UL 2560 system 

certification but which may be used within a UL 2560 certified 

system (e.g. universal transmitters and activity sensors).

Alarm 
Activation

Alarm 
Clearance

Low 
Battery

Missing 
Battery

LED Color

Red

Blue

Yellow

Yellow

LED 
Pattern

Rapid blink 
for five 
seconds, 
and then 
slow blink 
until alarm 
is cleared

Using 
alarm 
clearance 
card: six 
quick 
flashes

Using 
button 
pattern: 
two quick 
flashes 
after first 
three 
button 
presses, 
and then 
six quick 
flashes 
after the 
next three 
button 
presses

Blinks 
every five 
seconds 
until battery 
is replaced 
or until 
seven-day 
countdown 
expires

Steady 
glow for 
five 
seconds, 
then stops

Vibration 
Patterns

Vibrates for 
one second

N/A

N/A

N/A

More 
Informatio
n

Section 3.1

Section 3.2

Section 3.3

Section 
5.2

Usage Situation

OK to Use?

Cautions

Shower

Yes*

Do not spray water directly on the 
device at distances of less than 12 
inches; avoid spraying water at 
extremely high pressure.

Bath

Yes*

Momentary submersion is 
permissible at water temperatures 
less than 105°F. Extended 
submersion of the device is not 
recommended.

Rain

Yes*

Avoid extended exposure; wear 
the device under a sleeve, shirt, or 
jacket

Water exercise, 
swimming pool, 
hydrotherapy/hot 
tubs, steam 
rooms and 
saunas

No

Do not use the device during these 
activities. Please note that the  
IP67 rating does not test for 
exposure to liquids with a chemical 
content such as chlorine or salt 
water. Exposure to elevated water/
air temperatures or humidity levels 
in these settings may permanently 
damage the device.

Отзывы: