background image

6/19/17 04933F © Inovonics, 2017 - www.inovonics.com

EE1216 EchoStream

®

 Dual Input 

Universal Transmitter with Wall Tamper

Installation Instructions

1 Overview

The EE1216 dual input universal transmitter with wall tamper is 
designed for use with almost any standard contact or sensor, 
and includes two inputs for maximum flexibility. It is fully 
supervised and includes a wall tamper switch that notifies the 
system when the transmitter is removed from its mounted 
surface.

1.1 Inovonics Contact Information

If you have any problems with this procedure, contact Inovonics 
technical services:

• E-mail: [email protected].
• Phone: (800) 782-2709; (303) 939-9336.

1.2 EE1216 Internal Components

 Figure 1  

EE1216 components

1.3 What’s In the Carton

• One 3.0V lithium battery, Inovonics part number BAT604.
• Two wall mount screws.
• Two wall mount anchors.
• Two selection jumpers.
• One housing closure screw.

2 Installation and Startup

2.1 Installation Notes

• These products are designed to be maintained by 

professional security technicians.

• Products are tested for indoor use.
• All products should be manually tested weekly.

2.2 Install the Battery

1.

Use your thumb to depress the housing release tab on the 
bottom of the transmitter; separate the housing.

2.

Install the battery.

2.3 Wiring the Contacts

The transmitter has a three-terminal contact block that can 
connect inputs from one or two external contact loops. The 
middle terminal is a ground, which is shared by both contact 
loops. Input one can be configured for either a normally open or 
a normally closed contact loop; input two is always normally 
closed.

3.

Connect wiring for the inputs you will be using.

4.

If you are not using input two, connect wiring between the 
input terminal and the ground terminal to set it for normally 
closed.

2.4 Select Input Type 

The NO/NC selection pins allow the choice of a normally open or 
normally closed state for the contact circuit wired to the input one 
terminal. The terminal is shipped set for normally closed, with no 
selection jumper on the NO pins. If you need to set the terminal 
for normally open, you will need to configure the input type; 
otherwise, skip to section 2.5, “Select the EchoStream Select 
Compatibility”.
To configure the input type:

5.

Place a selection jumper on the NO/NC selection pins to 
select normally open.

6.

Press the reset button.

2.5 Select the EchoStream Select Compatibility

To meet ETSI requirements, Inovonics has developed a new line 
of EE 868MHz-only products. These new 868MHz-only products 
are compatible with older systems that include EchoStream 
select products. If you are using any ES products in your current 
system, you will need to enable EchoStream select compatibility 
on this new 868MHz-only product; if you are not using any 
EchoStream select products, skip to section 2.6, “Register the 
EE1216”. 
To enable/disable EchoStream select compatibility:

7.

Place a selection jumper on the enable EchoStream select 
compatibility selection pins.

8.

Press the reset button.

2.6 Register the EE1216

Transmitters must be registered with the system in order to be 
monitored and supervised. When supervised, the transmitter will 
send a check-in message to the receiver. Transmitters using the 
868MHz frequency range for Europe will send a check-in 
message every 12 minutes; all other transmitters will send a 
check-in message every three minutes. Each transmitter has a 
unique factory-programmed identification number. Refer to the 
receiver installation instructions for details on registering a 
transmitter.

9.

When prompted by the receiver to reset transmitter, press 
the reset button.

10.

Test the transmitter and ensure appropriate response.

For product and installation videos visit us at 
www.inovonics.com/videos or use the QR 
code below.

A

Housing tamper button

B

NO/NC selection pins

C

Transmit LED

D

Reset button

E

Wall-mount screw holes

F

Housing screw hole

G

EchoStream select compatibility 
selection pins

H

Input two

I

Ground

J

Input one

A

B

H

D

E

F

G

E

C

J

I