— 56 —
Header/Command
Parameter
Details
COM.NOHEADERSMODE=
COM Port No
Headers Mode
This defines how text is used if no headers are required.
0 = Text to DPS.
1 = Text to RT.
2 = Text to both DPS & RT.
TCP
n
.ENABLE=
TCP Enable
0 = TCP port disabled.
1 = TCP port enabled.
TCP
n
.ECHO=
TCP Echo
Echo defines whether all data received by the port is trans-
mitted back to the sender.
0 = Echo disabled.
1 = Echo enabled.
TCP
n
.REPLY=
TCP Reply
Reply defines whether OK or NO is transmitted to the sender
after the receipt of a valid/invalid command.
0 = Reply disabled.
1 = Reply enabled.
TCP
n
.PORT=
TCP Port
Sets the TCP port to receive data.
UDP
n
.ENABLE=
UDP Enable
0 = UDP port disabled.
1 = UDP port enabled.
UDP
n
.ECHO=
UDP Echo
Echo defines whether all data received by the port is trans-
mitted back to the sender.
0 = Echo disabled.
1 = Echo enabled.
UDP
n
.REPLY=
UDP Reply
Reply defines whether OK or NO is transmitted to the sender
after the receipt of a valid/invalid command.
0 = Reply disabled.
1 = Reply enabled.
UDP
n
.PORT=
UDP Port
Sets the UDP port to receive data.
UDP
n
.GROUP=
UDP Multicast
Group
Sets a UDP multicast group to join for receiving multicast
data.
0.0.0.0 disables multicast for this port.
WHITELIST.ENABLE=
Whitelist Enable
0 = IP whitelist disabled.
1 = IP whitelist enabled.
WHITELIST.IP
n
=
Whitelist IP Ad-
dress
Sets IP addresses from which data will be accepted. Data
received from any other IPs will be rejected.
ALARMS.DPS.ENABLE=
DPS Update
Alarm Enable
0 = DPS update alarm disabled.
1 = DPS update alarm enabled.
ALARMS.DPS.TIMEON=
DPS Update
Alarm Time On
1-240 = The number of minutes between receipt of the last
DPS message and triggering of this alarm.
ALARMS.RT.ENABLE=
RT Update Alarm
Enable
0 = RT update alarm disabled.
1 = RT update alarm enabled.
ALARMS.RT.TIMEON=
RT Update Alarm
Time On
1-240 = The number of minutes between receipt of the last
RT message and triggering of this alarm.
ALARMS.PILOT.ENABLE=
Pilot Loss Alarm
Enable
0 = Pilot loss alarm disabled.
1 = Pilot loss alarm enabled.
ALARMS.PILOT.TIMEON=
Pilot Loss Alarm
Time On
1-240 = The number of seconds between loss of pilot and
setting this alarm.
ALARMS.PILOT.TIMEOFF
=
Pilot Loss Alarm
Time Off
1-240 = The number of seconds between recovery of pilot
and clearing this alarm.
ALARMS.LOGEMAIL=
Alarm Log Email
Threshold
1-100 = The percent fullness of the alarm log at which an
email will be sent as a reminder about the alarm log fullness.