background image

Revision History  

                                                                                                                                                     

- 32 -

Revision History

Date 

Version 

Change Description

Oct. 2017

A00

First issue.

Apr. 2019

A01

Updated the cover.

Содержание MDKE9 Series

Страница 1: ...Park Liuxian Road Baocheng No 70 Zone Bao an District Shenzhen Tel 86 755 2979 9595 Fax 86 755 2961 9897 Service Hotline 400 777 1260 http www inovance com Suzhou Inovance Technology Co Ltd Add No 16...

Страница 2: ...and application maintenance and repair Read and understand the user guide before use Contact our customer service center if you have any question during the use Safety Instructions The drawings in the...

Страница 3: ...1 Summary 16 4 1 1 Main Interface 17 4 1 2 Help 18 4 1 3 Base Operation 18 4 1 4 Fault Viewing 18 4 1 5 Switching Operating Device 18 4 1 6 Connecting to the PC 19 4 2 Parameter Setting 19 4 2 1 Param...

Страница 4: ...Warning Warning sign indicates that failure to comply with the notice may result in server personal injuries or even death The Caution Caution sign indicates that failure to comply with the notice ma...

Страница 5: ...personal juries or equip ment damages Never stand or stay below the equipment when the equipment is lifted by hoisting equipment Installation Warning Read and comply with the safety instructions befor...

Страница 6: ...lding requirements the shielding layer of the shielded cable must be reliably grounded at one end After wiring make sure there are no fallen screws or exposed wire inside the cabinet or product Power...

Страница 7: ...lacement Never perform any inspection or maintenance operations at power on Failure to comply may result in electric shock Before inspection or maintenance wait at least 10 minutes so that residual vo...

Страница 8: ...gns Instructions of safety signs are as follows Safety signs Instructions Read this notice before installation and operation Failure to comply may result in electric shock Do not remove the cover with...

Страница 9: ...ommissioning assistant for single drives such as MD200 series MD310 series MD500 series MD500E series and MD290 series 2 1 Nameplate Figure 2 1 Nameplate MODEL MDKE9 S N 01040037H500025 Suzhou Inovanc...

Страница 10: ...uch as product model and serial number Battery cover The battery and SD card slot are beneath the cover The battery provides power to the real time clock The SD card stores factory parameters and real...

Страница 11: ...Loc Rem Switchover key To switchover between local and remote control Direction To use and to select items in the menu and list scroll the text page and adjust the values time setting password enteri...

Страница 12: ...cifications Table 2 4 General Specifications S N Item Running Storage Transportation 1 Working temperature range 20 55 40 70 40 70 2 Attitude requirement 4000 m 3 Relative humidity 95 non condensing 4...

Страница 13: ...E9 with AC Drive Open the external panel cover on MD310 AC drive connect the RJ45 connection terminal at the back of the MDKE 9 via a network cable optional FE D REW FE D REW LO CAL RUN ERR MDKE9 Exte...

Страница 14: ...nd the PC 1 Open the cover at the USB connection terminal Figure 3 1 Connect MDKE9 with PC step 1 MDKE9 2 Plug in the USB cable suggest to use cable with Ferrite toroidal then connect the cable to PC...

Страница 15: ...nel base installation Use the four screws 1 as shown in figure 3 4 to fix the base on the cabinet door Figure 3 4 Installing base on the cabinet door Installation base 1 1 1 1 Sheet mental Cabinet doo...

Страница 16: ...index finger and middle finger to release the MDKE9 then pull the upper end of the MDKE9 out of the base slot Figure 3 6 Sheet metal slot dimensions Figure 3 7 Base mounting hole size 4 5 79 70 53 3...

Страница 17: ...structure diagram Parameters Group Parameter Step Ctrl Manufacturer Adjust Authority Fault records Alarm Change Shortcut History alarm System set Backlight Protect time Contrast Date Time Language Ab...

Страница 18: ...all not be displayed then Device list List of devices connected to the network Menu to enter the function menus of the MDKE9 At main interface you can monitor the monitoring equipment status such as s...

Страница 19: ...trol mode between local and remote for the same equipment 4 1 4 Fault Viewing Table 4 2 Fault description Task Action Check the current faults Open menu status monitoring fault status Open the help in...

Страница 20: ...erface On the main interface enter any random function group move the cursor to the required function code and press and the at the same time to add the function code to the shortcut interface Delete...

Страница 21: ...re the parameter to default value and then press to save the modification 2 Modifying select list parameters Take setting F0 00 to 2 that is to set GP type to P type as the example The setting steps a...

Страница 22: ...eleted and press and at the same time to delete the function code from the short cut interface 4 3 Status Monitoring On status monitoring interface you can view the current status of the fault equipme...

Страница 23: ...re stored on the SD card make sure that you have correctly installed the SD card 4 4 Equipment Operating You can perform commissioning on equipment operating menu Table 4 5 Equipment operating Task Ac...

Страница 24: ...pdate the program of the MDKE9 enter the manufacturer password to log in to the MDKE9 Figure 4 9 Example of login Inverter 01 Paramater Set 02 Status Monitor 03 Device Control Back Select 18 00 02 Loc...

Страница 25: ...the MDKE9 4 7 System Operation You have to log in the MDKE9 before using the functions such as parameter copy update device update MDKE9 under system control Refer to section 4 5 1 for details For det...

Страница 26: ...s the user defined part 02 March 13 49 05 Press to read and copy the parameters after the file name is set Handle succeed will display on the interface after reading and copying parameter is finished...

Страница 27: ...3 Note All parameter files that are copied saved and read are stored in SD card ensure that the SD card is properly installed before using the parameter copy function Example Copy all the parameters i...

Страница 28: ...g completes Wait until the burning completes Note Copy the update file from the PC to X SYS PROGRAM For details of the storage method of the SD card file see 5 3 SD Card Replacement 4 7 3 Update Devic...

Страница 29: ...procedure ends Figure 4 16 Example of program update processing Select File factorys bin Back Select MDKE9 20170428 01s bin Device will reboot and update Note Copy the update file from the PC to X SY...

Страница 30: ...through the keys is normal Check whether there is abnormal smell Periodical Inspection 1 year Check whether the fastening parts get loosened Check whether there is overheat Check whether the USB conn...

Страница 31: ...ce the SD card Step 1 Use a slotted screwdriver or fingers to remove the battery cover Step 2 Push the metal cover towards the unlock direction to release the SD card Step 3 Lift the metal cover and p...

Страница 32: ...5 Maintenance and Repair 31 5 Step 5 Put the battery cover back Note Plug and play is not supported Replace the SD card when the MDKE9 is powered off...

Страница 33: ...Revision History 32 Revision History Date Version Change Description Oct 2017 A00 First issue Apr 2019 A01 Updated the cover...

Страница 34: ...Park Liuxian Road Baocheng No 70 Zone Bao an District Shenzhen Tel 86 755 2979 9595 Fax 86 755 2961 9897 Service Hotline 400 777 1260 http www inovance com Suzhou Inovance Technology Co Ltd Add No 16...

Отзывы: