MD021 Plastic Wire Drawing Machine User Manual
When "Frequency source selection" (F0-01) is set to 1 (Special
wrap-up mode for wire drawing machine), the inverter reports Err17 if
the swing link (AI) voltage reduces to the value of "Lower limit for
wire-break detection" (F2-06) and remains during "Judging delay time
of wire-break detection" (F2-07).
The parameter "Lower limit for wire-break detection" (F2-06) is set
based on the percentage of the swing link (AI) maximum input
voltage (5 V).
Function
Code
Name
Range
Default
F2-08
Lower
limit
frequency of wire
drawing machine
0.01
Hz
to
50.00 Hz
2.00 Hz
This parameter specifies the lower limit frequency of the wire drawing
machine. This parameter is valid only when "Frequency source
selection" (F0-01) is set to 1 (Special wrap-up mode for wire drawing
machine).
Function
Code
Name
Range
Default
F2-09
Enable
frequency setting
by
operation
panel
0: Not enable
1: Enable
0
F2-10
Frequency set by
0.01
Hz
to