5.

 

Username and password configuration 

 

 

In Login Config menu you can change the username and password used to access 

the  web-server.  Maximum  length  for  both  fields  is  11  symbols.  If  you  forget  your 
credentials you can perform a hardware reset to recover default settings: 
 

Username: root 

Password: admin 

 

When you click the 

Save Config

 button a validation check is performed. If there is 

invalid data in one or more fields – they will be colored in red. If all the input data are 
correct SIGI will save the parameters and will reboot with the new configuration.

 

 

Содержание SIGI

Страница 1: ...SIGI User Manual v2 0 Inova bg Ltd 2018 Inova bg Ltd SIGI...

Страница 2: ...Homepage 5 4 Configuration of the main parameters 6 5 Username and password configuration 8 6 Reboot 9 7 Hardware reset 9 8 SiGi Receiver Software 9 9 Installing Virtual Serial Port Driver 11 9 1 Win...

Страница 3: ...nel The device has an HTML server for easy configuration and status check protected with a username and a password On the front panel there is RS232 and Ethernet connectors and four LED indicators P 1...

Страница 4: ...enter the SIGI s address http 192 168 1 220 or the new one if you already change it If the device is accessible from that computer a connection will be established and you will be prompt to enter use...

Страница 5: ...Inova bg Ltd 2018 Page 5 of 16 3 Homepage On the homepage you can find main information about the device and the current status of the connections and also the status of the GPRS network connection an...

Страница 6: ...to identify devices if you have more than one connected to one network Obtain an IP address automatically via DHCP IP address is received automatically from a DHCP server in the current network If yo...

Страница 7: ...tor must be entered If only IP network is used these fields can be empty In SIM PIN Code the PIN code must be entered If the SIM card doesn t use PIN code this field has no role empty or not APN Acces...

Страница 8: ...r both fields is 11 symbols If you forget your credentials you can perform a hardware reset to recover default settings Username root Password admin When you click the Save Config button a validation...

Страница 9: ...nnect from power supply push and hold the button for hardware reset and reconnect to the power supply Hold the button for 5 seconds until the yellow LED G is blinking Once the LED goes constantly ON y...

Страница 10: ...can be set to use Real or Virtual COM port To add new virtual COM port press the Add Virtual COM Port Button In the Log slider tab there is a log of all the events that happened while the software was...

Страница 11: ...tic 9 1 Windows 8 1 10 x64 unsigned driver installation 64 Bit editions of Windows 8 1 Windows 10 require digitally signed drivers To disable driver signature verification use the following steps Hold...

Страница 12: ...SIGI User Manual v2 0 Inova bg Ltd 2018 Page 12 of 16 Then Startup Settings Since we are modifying boot time configuration settings you will need to restart your Computer one last time...

Страница 13: ...va bg Ltd 2018 Page 13 of 16 Finally you will be given a list of startup settings that you can change The one we are looking for is Disable driver signature enforcement To choose the setting you will...

Страница 14: ...SIGI User Manual v2 0 Inova bg Ltd 2018 Page 14 of 16 9 2 Driver Installation Automatic Start the SiGi Receiver as Administrator and follow the steps...

Страница 15: ...I User Manual v2 0 Inova bg Ltd 2018 Page 15 of 16 9 3 Driver Installation Manual If automatic installation cannot successfully install the driver please try to install it manually by following the st...

Страница 16: ...SIGI User Manual v2 0 Inova bg Ltd 2018 Page 16 of 16...

Отзывы: