COMMAND

(CMAD=1, CMCK=0)

C

M

D

TO Panelplayer

FROM Panelplayer

NOTE 1

NOTE 2

HEX

ASCII

HEX

ASCII

STATUS REQUEST

30 05 30 31 33 30

ENQ

0130

02 30 31 33 30 53 4D 30 30 03

STX

0130SM00

ETX

if in stop mode

02 30 31 33 30 50 4D 30 30 03

STX

0130PM00

ETX

if in play mode

STOP

31 05 30 31 33 31

ENQ

0131

06 30 31 33 31

ACK

0131

PLAY FIRST

32 05 30 31 33 32

ENQ

0132

06 30 31 33 32

ACK

0132

if in stop mode

15 30 31 33 32 33 31

NAK

013231

if in play mode (Panelplayer

doesn’t perform the action)

PLAY NEXT

33 05 30 31 33 33

ENQ

0133

06 30 31 33 33

ACK

0133

if in stop mode

15 30 31 33 33 33 31

NAK

013331

if in play mode (Panelplayer doesn't jump to the

following file, it is first required to send a stop)

PLAY PRIOR

34 05 30 31 33 34

ENQ

0134

06 30 31 33 34

ACK

0134

if in stop mode

15 30 31 33 34 33 31

NAK

013431

if in play mode (Panelplayer doesn't jump to the

previous file, it is first required to send a stop)

PLAY FILE song.mp3

50 05 30 31 35 30 73 6F 6E 67

ENQ

0150song 06 30 31 35 30

ACK

0150

if in stop mode

15 30 31 35 30 33 31

NAK

015031

if in play mode (Panelplayer doesn’t perform the

action, it is first required to send a stop)

PLAY FILE fire.mp3

50 05 30 31 35 30 66 69 72 65

ENQ

0150fire

06 30 31 35 30

ACK

0150

if in stop mode

15 30 31 35 30 33 31

NAK

015031

if in play mode (Panelplayer doesn’t perform the

action, it is first required to send a stop)

PLAY FILE 2 song.mp3
(automatic STOP before
PLAY)

51 05 30 31 35 31 73 6F 6E 67

ENQ

0151song 06 30 31 35 31

ACK

0151

if in play mode (Panelplayer restarts from the

beginning of the interrupted file)

06 30 31 35 31

ACK

0151

if in stop mode

SET VOLUME (0 db - 14)

52 05 30 31 35 32 30 30 31 34

ENQ

01520014 06 30 31 35 32

ACK

0152

SET VOLUME (-23 db - 4)

52 05 30 31 35 32 30 30 30 34

ENQ

01520004 06 30 31 35 32

ACK

0152

SET VOLUME (off - 00)

52 05 30 31 35 32 30 30 30 30

ENQ

01520000 06 30 31 35 32

ACK

0152

SET TREBLE (12 db – 20)

53 05 30 31 35 33 30 30 32 30

ENQ

01530020 06 30 31 35 33

ACK

0153

SET BASS (12 db – 20)

54 05 30 31 35 34 30 30 32 30

ENQ

01540020 06 30 31 35 34

ACK

0154

SET LOUDNESS(12 db-20)

55 05 30 31 35 35 30 30 32 30

ENQ

01550020 06 30 31 35 35

ACK

0155

VERSION OF
FIRMWARE

35 05 30 31 33 35

ENQ

0135

02 30 31 33 35 50 32 30 35 03

STX

0135P205

ETX

P = Panelplayer
x = version
xx = Release

STATE OF INPUTS

37 05 30 31 33 37

ENQ

0137

02 30 31 33 37 30 30 30 30 30
30 30 30 03

STX

013700000000

ETX

a b c d e f g h

a = IN 8
b = IN 7
c = IN 6
d = IN 5
e = IN 4
f = IN 3
g = IN 2
h = IN 1

Содержание Panelplayer

Страница 1: ...0 0 USER MANUAL 0 Version 1 4...

Страница 2: ...he warranty only covers damage to the product which makes it work badly 4 Work under warranty will only mean repairing or replacing free of charge any parts acknowledged to be defective during manufac...

Страница 3: ...4 3 How it is managed by Panelplayer 4 4 Preparing the file 4 5 Memorising the files in the Flash memory 4 6 Audio adjustment parameters 4 7 Timing and switchover parameters 4 8 Diagram of the operati...

Страница 4: ...reply by Panelplayer 9 5 Transmitting a command by master 9 6 How to read the figures of the dedicated protocols 9 7 When the Master delivers a command to Panelplayer 9 8 Basic format of the dedicated...

Страница 5: ...ty The right compromise which guarantees a quality comparable to that of a Compact Disc is 128 Kbps thousands of bits per second which represents the most widely used manner and reduces the size of an...

Страница 6: ...the power socket before cleaning Clean the device using a soft dry cloth Do not use liquids or spray which can contain flammable substances Obsolete devices disposal When you find this picture on a d...

Страница 7: ...longed pressure reduce output volume STOP PLAY brief pressure next MP3 file prolonged pressure increase output volume 4 Red LED lit device is live 5 Green LED lit blinking MP3 file playing Panelplayer...

Страница 8: ...or 6 m3u playlist direct or bit 5 in binary combination Configurable for serial RS485 communication see chap 9 IN OUT7 Multi function input output for activating 64 mp3 file or 7 m3u playlist direct...

Страница 9: ...D lights up when it is turned on with active feed 3 4 Logical inputs Panelplayer has six eight multi function logical inputs to control the playing of the playlists or direct calling up of individual...

Страница 10: ...9 1 3 7 Pre amplified audio input Pre amplified STEREO L R audio input for outside music source SAT DAB CD etc with Mixer function to mix a music source with scheduled commercials extractable termina...

Страница 11: ...ontent of the configuration file Each line of the configuration file consists of Mnemonic code of the parameter to be set It always consists of four CAPITAL alphanumeric characters and must always be...

Страница 12: ...cument as text only otherwise control characters would be inserted which would make it impossible for Panelplayer to interpret this file 4 5 Memorising the files in the flash memory The configuration...

Страница 13: ...4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Level OFF 55 dB 35 dB 28 dB 23 dB 20 dB 17 dB 14 dB 12 dB 10 dB 8 dB 6 dB 4 dB 2 dB 0 dB 2 dB 4 dB 6 dB 8 dB 10 dB 12 dB LLOU loudness level Value 0 1 2 3...

Страница 14: ...in cascade value between 0 and 20 in decimal TFOU fade OUT setting the fading time of the INL INR before playing the MP3 file spot Value 1 2 4 5 6 9 10 11 14 15 16 19 20 21 24 25 26 29 30 Time 1 10 se...

Страница 15: ...Panelplayer User Manual v 1 4 Page 14 4 8 Diagram of the operating parameters...

Страница 16: ...e input is connected to the ground GND of the device 1 active high input mode the functioning of the input is applied with a positive voltage between 5 and 12Vdc TPCM Time persistence input command mo...

Страница 17: ...alue between 0 and 20 in decimal PYDT activation infrared movement sensor PYDT 1 IR sensor activated 0 sensor deactivated PYDL pause between two activations of the IR sensor Value 0 1 2 3 4 5 10 20 30...

Страница 18: ...w line of text with this and to separate the hours from the minutes using the character On the same line you must then introduce the names of the MP3 audio files max 8 characters You can choose among...

Страница 19: ...impsest 500 spots file 5 3 MIXER function Panelplayer has an audio input for connection to outside music sources with a mixer function to mix this source with the files played by flash memory see par...

Страница 20: ...5 01 005 Example with names intro part 1 part 2 monologu music part 3 finale IMPORTANT Rename the MP3 audio files with numbers or names with max 8 characters Do not write in the extension mp3 Max 500...

Страница 21: ...other inputs does not influence the playing of the file The position of the last item played is stored in memory in order to start out again always by the next one in case of restart The playlist is...

Страница 22: ...erway and activates the relative playlist 6 7 MPLL 13 Standard playlist Operating mode as MPLL 11 except Repeated activations or deactivations of the same logical input does not influence the playing...

Страница 23: ...device is switched on or when the flash memory is inserted the user can run through the files just like listening to an audio CD by using the buttons on the front of the device or by activating the c...

Страница 24: ...player mode the logical inputs can be used for player control previous MP3 file stops file reproduction Panelplayer restarts from the beginning of the interrupted file next MP3 file reduce output vol...

Страница 25: ...g the inputs in binary combination one can launch the playing of a maximum of 255 messages naming the audio files as shown on the following table INPUT FILE INPUTS BINARY COMBINATION 1 2 3 4 5 6 7 8 m...

Страница 26: ...IN 2 IN 3 IN 4 IN 6 1 1 1 1 O 1 O O 47 IN 1 IN 2 IN 3 IN 4 IN 6 O O O O 1 1 O O 48 IN 5 IN 6 1 O O O 1 1 O O 49 IN 1 IN 5 IN 6 O 1 O O 1 1 O O 50 IN 2 IN 5 IN 6 1 1 O O 1 1 O O 51 IN 1 IN 2 IN 5 IN 6...

Страница 27: ...O 1 O 93 IN 1 IN 3 IN 4 IN 5 IN 7 O 1 1 1 1 O 1 O 94 IN 2 IN 3 IN 4 IN 5 IN 7 1 1 1 1 1 O 1 O 95 IN 1 IN 2 IN 3 IN 4 IN 5 IN 7 O O O O O 1 1 O 96 IN 6 IN 7 1 O O O O 1 1 O 97 IN 1 IN 6 IN 7 O 1 O O O...

Страница 28: ...O 1 O 1 O O O 1 138 IN 2 IN 4 IN 8 1 1 O 1 O O O 1 139 IN 1 IN 2 IN 4 IN 8 O O 1 1 O O O 1 140 IN 3 IN 4 IN 8 1 O 1 1 O O O 1 141 IN 1 IN 3 IN 4 IN 8 O 1 1 1 O O O 1 142 IN 2 IN 3 IN 4 IN 8 1 1 1 1 O...

Страница 29: ...84 IN 4 IN 5 IN 6 IN 8 1 O O 1 1 1 O 1 185 IN 1 IN 4 IN 5 IN 6 IN 8 O 1 O 1 1 1 O 1 186 IN 2 IN 4 IN 5 IN 6 IN 8 1 1 O 1 1 1 O 1 187 IN 1 IN 2 IN 4 IN 5 IN 6 IN 8 O O 1 1 1 1 O 1 188 IN 3 IN 4 IN 5 IN...

Страница 30: ...IN 1 IN 2 IN 3 IN 6 IN 7 IN 8 O O O 1 O 1 1 1 232 IN 4 IN 6 IN 7 IN 8 1 O O 1 O 1 1 1 233 IN 1 IN 4 IN 6 IN 7 IN 8 O 1 O 1 O 1 1 1 234 IN 2 IN 4 IN 6 IN 7 IN 8 1 1 O 1 O 1 1 1 235 IN 1 IN 2 IN 4 IN 6...

Страница 31: ...o run in playlist mode playing the musical items PLAYLIST TXT the other programmed to run according to schedule PALIN TXT plays the commercial spots Panelplayer with playlist Panelplayer with palimpse...

Страница 32: ...greater power To enable this operational mode in addition to having a different connection to the output clams it is necessary to set the following configuration parameters in the config txt file OMO...

Страница 33: ...unication consents the connection in bus of up to 32 devices with a maximum distance of 50 metres The Panelplayer devices connected to the RS485 bus can not autonomously begin communication but they c...

Страница 34: ...mpers IN5 and IN6 inputs with logical operation Default Position P1 and P2 jumpers IN5 and IN 6 inputs enabled to the operation as RS485 serial port To move the bridges raise the cover of the device a...

Страница 35: ...the outside device with which Panelplayer is to communicate IMPORTANT To make the modification of these parameters effective it is necessary to restart Panelplayer after having introduced the flash me...

Страница 36: ...y 2 even parity CMSB DEFAULT 1 Number of Stop Bits 1 1 stopBit 2 2 stopBits CMDB DEFAULT 8 Number of data bits 7 7 bits per datum 8 8 bits per datum CMDR DEFAULT 0 Minimum delay between end of recepti...

Страница 37: ...moment the last command received by Panelplayer has been completely performed IMPORTANT when one is using the RS485 bus only on a duplex cable remember to bear in mind or to ignore the echo of the co...

Страница 38: ...gure to the right of the character ENQ 9 8 Basic format of the dedicated protocols Panelplayer manages up to four dedicated protocols The definition of which of these four protocols must be used by th...

Страница 39: ...a number that allows the system Master to establish communication with one of the various modules connected to the same serial line The value of this address is defined in Panelplayer through a confi...

Страница 40: ...ent of the CheckSum is established by the CMCK parameter of the configuration file If CMCK 1 has been set CheckSum will be calculated automatically and added to the term of the reply pack the one begi...

Страница 41: ...ce E N Q A D D C M D DATA S T X E T X A D D C M D DATA Master Panelplayer Transmission sequence E N Q A D D C M D A C K Reading the data of the Panelplayer from the master Command transmission from ma...

Страница 42: ...Transmission sequence E N Q A D D C M D A C K Reading the data of the Panelplayer from the master Command transmission from master to Panelplayer C H K C H K C H K A D D C M D N A K E R R 1 The CheckS...

Страница 43: ...D C M D DATA S T X E T X A D D C M D DATA Master Panelplayer Transmission sequence E N Q A D D C M D A C K Reading the data of the Panelplayer from the master Command transmission from master to Pane...

Страница 44: ...quence E N Q A D D C M D A C K Reading the data of the Panelplayer from the master Command transmission from master to Panelplayer C H K C H K C H K A D D C M D N A K E R R 1 The CheckSum is introduce...

Страница 45: ...ters only None PLAY File2B 57 Name of file without extension 4 characters only None Version of firmware 35 None P Panelplayer x version xx Release Version State of inputs 37 None a b c d e f g h a IN...

Страница 46: ...ed value 21H Wrong value in the parameter of the command SET_Treble It could be more than the maximum permitted value 22H Wrong value in the parameter of the command SET_Bass It could be more than the...