Industrial rated design 

 

Standalone - bench top or fixed mounting 

 

Front panel controls & indication 

 

Suitable for float charging of lead acid batteries 

 

Suitable for parallel operation 

 

Conservative design for long life 

 

Precise voltage and current control 

 

Optional temperature compensation for charging 

 

Optional DC input 

 

Optional communications port:  RS232, RS485 or 
Ethernet,  protocols Modbus, SNMP or ASCII code 

 

 

 

♦ 

24 Month Warranty 

STANDARDS

 

EMI 

 

Safety

 

Input  ▪ standard 
 

▪ option 

 
Fusing 
 
Overload protection

 

 
 

 

Isolation 

 

Over voltage protection

 

 

Efficiency 

 

Inrush current

 

 
Output power

 

 

Output voltage

 

 
Line regulation

 

 

Load regulation 

 

Noise 
 
Drift 

 

Hold-up time

 

 

Thermal protection

 

 

Parallel operation 

higher power 

N+1 redundancy 

 
Alarms 

 

 
 
 
 
 

  

 

 
Alarm contacts 

 
 
 

ELECTRICAL  

230VAC (180 - 264), 45-65Hz 
110VAC (88 -132), 45-65Hz   
 
Internal  input fuse 
 
Constant current limit under overload and 
short circuit conditions (except DC input ver-
sions which have primary current limit) 
 
1KV DC input - output / earth 
 
130% of nominal output voltage 
 
> 85% 
 
Soft start circuit  
 
750W 
 
Refer to model table 
 
<0.2% over AC input range 
 
<0.4% open circuit to 100% load 
 
<1% 
 
0.03% / °C 
 
15 - 20 ms without battery 
 
Yes, self resetting 

 

Yes 
Addition of external output diodes optional 
Use with external output diodes 
 

 

Mains fail

 

 

DC low 

(Battery low or PSU low) 

 

- Charger: set at 1.83V/cell 
- PSU: set at 83% V out

 

• 

DC high 

 
C - NO - NC changeover rated 1A /50V DC, 
32VAC 

ENVIRONMENTAL

 

Operating   
temperature 

 

Storage temperature 

 

Humidity 
 
Cooling 

 

 

0 to + 50 °C ambient at full load 
De-rate linearly >50 °C to no load @ 70 °C 

 

-10 to 85 °C ambient 

 

0 - 95% relative humidity non-condensing 
 
Fan cooled 
 
 

To CISPR 22 / EN55022 class A 

 

To IEC950 / EN60950 / AS/NZS3260 

ACCESSORIES SUPPLIED 

Mounting feet  together with screws 
AC power cord 1.5m  with IEC320 socket and NZ/Aust plug 
Mating screw-terminal plug for alarm outputs 
Crimp lugs for stud terminal versions 
DC screw terminal plug-in connector for 

‘X’ 

version

 

 Ideal as a Standby Float Charger 
 for lead acid batteries 

PHYSICAL

 

AC input connector 
 
DC connections 
 
Alarm connections 
 
Enclosure 
 
Dimensions 
 
Weight 

 

Indication LEDs 
 

 

Standby switch 

 

 
 

IEC320 inlet socket  

 

M8 brass stud or plug in/screw terminal block 
 
Plug-in screw terminal block 

 

Powder coated steel 
 
225W x 70H x 304D mm (excl. terminals) 
 
4.3 Kg 
 

Standard:

 

Power OK, Standby 

With alarms:

 DC OK, Power OK, Standby 

 
Turns off DC output of PSU 

Optional internal V/I 

meter shown 

SPECIFICATIONS   

All specifications are typical at nominal input, full load and at 20°C unless otherwise stated. 

DC power supply /charger with 3 alarm relay outputs 

Содержание SR750L

Страница 1: ...ability accepted for errors or omissions 1 User Manual SR750L AC DC POWER SUPPLY FLOAT CHARGER with alarms RS485 comms www innovative co nz Phone 64 9 835 0700 Fax 64 9 837 3446 NZ Freephone 0800 654...

Страница 2: ...of reduced effi ciency Water Dust Every effort must be made in the installation to minimise the risk of ingress of water or dust Water will almost always cause instant failure The effects of dust are...

Страница 3: ...each polarity both terminals must be used This is to ensure that the current rating of the terminal block is not exceeded CONNECTION LAYOUT 3 LED INDICATION CODES DC OK LED indicates DC output is pre...

Страница 4: ...C 15 20 ms without battery Yes self resetting Yes Addition of external output diodes optional Use with external output diodes Mains fail DC low Battery low or PSU low Charger set at 1 83V cell PSU set...

Страница 5: ...220VDC 180 270 Please note that an external fuse or MCB must be fitted on the output for short circuit protection Detects leakage to earth of DC output and provides relay output Code ALARM EFDM 20 60V...

Страница 6: ...arallel for increased power or parallel redundancy Figure 1 below shows two SR750L units connected with external diodes It is essential that the wiring from each unit to the load is kept identical for...

Страница 7: ...Specifications are subject to change without notice No liability accepted for errors or omissions 7 Notes Notes Notes Notes...

Страница 8: ...746 New Zealand TERMS OF WARRANTY Innovative Energies Ltd warrants its power supplies for 24 months two years from date of shipment against material and workmanship defects Innovative Energies liabili...

Отзывы: