background image

LIMITED WARRANTY

INNOVATIVE CIRCUIT TECHNOLOGY LTD.

26921 GLOUCESTER WAY     LANGLEY, BRITISH COLUMBIA, CANADA    V4W 3Y3

T

 604.856.6303     

F

 604.856.6365     

www.ictcorporate.com

ICT Limited Warranty is only intended for the benefit of the original 
Purchaser  of  this  product.  This  Warranty  is  not  transferable  or 
assignable  without  the  prior  written  permission  of  ICT.  ICTʼs  sole 
obligation and liability under this warranty is limited to either repairing 
or replacing defective products at the sole discretion of ICT. When 
repairing or replacing the products, ICT may use products or parts 
that are new, equivalent to new or re-conditioned. Parts repaired or 
replaced  during  the  warranty  period  will  be  under  warranty  for  the 
remainder of the warranty period.

The warranty period on ICT products purchased new from ICT is two 
years. The warranty period for a repaired product or part thereof is 
ninety (90) days or the remainder of the unexpired term of the new 
product  warranty  period,  whichever  is  greater.  Repair  or 
replacement  of  a  defective  product  or  part  does  not  extend  the 
original warranty coverage period. 

No  claim  will  be  accepted  unless  written  notice  of  the  claim  is 
received  by  ICT  in  accordance  with  ICTʼs  Return  Material 
Authorization  (RMA)  procedure,  as  soon  as  reasonably  possible 
after the defect is discovered. A valid product serial number must be 
provided  with  the  RMA  claim  to  prove  eligibility.  The  RMA  form  is 
available 

on 

the 

ICT 

website 

at 

www.ict-power.com/support/warranty-repair/. 

The Purchaser shall at their own risk and cost return the defective 
product to ICTʼs factory or designated repair center once an RMA is 
issued by ICT. Return of the products to the customer after repair is 
completed shall be prepaid by ICT unless otherwise mutually agreed 
between the parties. Products shipped to ICT which have incurred 
freight damage will not be covered by this Warranty and any repairs 
or  replacement  parts,  components  or  products  needed  will  be 
invoiced in the full current price amount and returned freight collect 
to  Purchaser.    It  is  the  Purchaserʼs  responsibility  to  check  the 
product upon receipt for any damage during shipping and to contact 
the  carrier  or  shipper  regarding  such  damage.  Product  that  is 
returned  as  defective,  which  is  determined  to  operate  within 
published  specifications  will  be  returned  to  the  Purchaser  freight 
collect. 

This  Warranty  will  be  void  if  the  product  has  been  subjected  to 
misuse, neglect, accident, exposure to environmental conditions not 
conforming to the productsʼ limits of operation, improper installation 
or  maintenance,  improper  use  of  an  electrical  source,  defects 
caused by sharp items or by impact pressure, a force majeure event,  
has  been  modified  or  repaired  by  anyone  other  than  ICT  or  its 
authorized  representative,  has  been  subjected  to  unreasonable 
physical,  thermal  or  electrical  stress,  improper  maintenance,  or 
causes  external  to  the  unit  including  but  not  limited  to  general 
environmental  conditions  such  as  rust,  corrosive  atmospheres, 
sustained temperatures outside the specified operating range of the 
equipment,  exposure  to  power  surges  and/or  electrical  surges, 
improper grounding, mould or dust, animal or insect damage, water 
damage or immersion in liquid of any kind.

ICT  does  not  control  the  installation  and  use  of  any  ICT  product. 
Accordingly, it is understood this does not constitute a warranty of 
performance or a warranty of fitness for a particular purpose.

STANDARD FEATURES AND OPTIONS (continued)

Input Fuse Protection protects against over current at the input 
of each module and on the backplane.

13

12

11

10

9

8

7

6

5

4

3

2

1

25

24

23

22

21

20

19

18

17

16

15

14

STATUS

FUNCTION

+15V supply

AC Power Good Signal (5 VDC = good)

Not Connected

Fan Fail (5 VDC = ok, 0 VDC = fail)

Not Connected

System current (0 VDC to 5 VDC = 0A to maximum system current)

Module 1 check (5 VDC = good)

Module 2 check (5 VDC = good)

Module 3 check (5 VDC = good)

Module 4 check (5 VDC = good)

Not Connected

Over-temperature sense (5 VDC = fail)

System output voltage sense

Signal Ground

PIN

1

2

3

4

5

6

7

8

9

10

11

12

13

14-25

The N+1 is equipped with a 25 pin D-Sub female connector (behind 
“STATUS  CONNECTOR”  panel  on  the  rear  of  the  unit)  with  the 
following pinout:

The  unit  features  protection  in  the  event  of  faults,  transients 
and other abnormalities.

LED Status Display (Standard)

A green LED status indicator is provided in the top right to indicate 
that  there  is  a  DC  voltage  present  at  the  output  terminals  of  the 
power supply.

Protection Features (Standard)

A green LED is provided in the top left for indication of the presence 
of AC voltage.

Two  LED  indicators  are  provided  for  each  of  the  four  internal 
modules.  A green LED will be lit to indicate that there is a voltage 
present at the output of the module.  A yellow LED will be lit if the 
module voltage is not present, either due to a fault or absence of 
the module.

Current Limit and Foldback protection are present on each module 
to  prevent  the  load  from  drawing  current  above  the  maximum 
allowable  value.  If  an  excessive  load  is  drawn  the  output  voltage 
will start to fold back, and in the case of a hard short the current 
will be reduced as well.

Surge protection is provided on the backplane and each module to 
protect against input voltage transients. 

DESCRIPTION OF OPERATION

The N+1 redundant power system consists of a backplane and 
up  to  4  modules.  Each  module  is  a  400+  watt  DC  power 
supply. They  are  highly  efficient  current  mode  power  supplies 
with electronic current and voltage foldback protection.

For  true  N+1  operation,  each  module  includes  a  redundant     
OR-ing diode. This diode ensures that no matter what type of 
failure occurs in one of the power modules, it will not affect the 
DC  bus.  Each  one  of  these  highly  reliable  power  modules  is 
connected through the system backplane. 

Through the backplane, each module is connected to create an 
active  load  sharing  network.  This  feature  forces  all  of  the 
modules to share the load evenly. 

ADJUSTMENT AND SERVICING

Remove  the  three  screws  located  on  the  top  of  the  system 
cover using a Phillips screwdriver. Then loosen the four screws 
on the sides of the case. You can now remove the lid.
Each  module  is  secured  with  3  screws.  Remove  the  screws 
using a Phillips screwdriver.
To remove a module, pull the module away from the backplane 
until  it  is  disconnected  from  the  quick  connector  and  then  lift 
the end up carefully.

STANDARD FEATURES AND OPTIONS

Battery Backup (Standard)

During normal operation, the power supply will provide power 
to the output while float charging the battery that is connected 
at  the  battery  backup  output.  In  the  event  that  the AC  power 
source is interrupted, the battery will supply power to the load 
through  an  isolation  diode;  however,  the  load  voltage  will  be 
0.4V lower than the battery voltage. The power resistors used 
to float charge the battery limit the charging current to about 5 
Amps.    During  battery  operation  the  fans  are  thermally 
controlled to conserve power.

Removal of Module

Installation of Module

To  install  a  module,  follow  the  steps  to  remove  a  module  in 
reverse. Pay special attention to the five spring clips in the metal 
heat sink of the module. These should be tight and care should be 
taken not to dislodge them.

Before opening the cover, be sure to turn off the unit and unplug 
any  power  sources  entering  the  unit.   This  includes  both  the AC 
power  souce  and  any  battery  connections.    A  full  manual  with 
more detailed instructions is available on request.

An  optional  LCD  display  is  available  for  the  system.  This  display 
shows  the  output  voltage,  current,  and  module  status.  A  plug 
symbol indicates that AC power is available, while a battery symbol 
indicates  that  the  unit  is  running  on  the  backup  batteries.    The 
display is backlit for better contrast in a wide range of ambient light 
conditions.

LCD Display (M Option)

Protection Features (Continued)