Innovative Cleaning Equipment SP-2SL Скачать руководство пользователя страница 3

 Page 3 of 4   | 04282014

User Manual: 2 Gallon Pump-Up Spray Unit | English

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

Operation Instructions:

1.  Ensure all air pressure is released from unit by twisting the 

pressure relief valve (PUF-PRV-2) clockwise 1/2 turn.

2.  Unscrew the pump assembly (PUFPA-2) from the tank by 

twisting the pump handle counter-clockwise.

3.  Follow all instructions from chemical manufacturer. Fill 

tank with pre-mixed solution up to the first band, or 1 gal 

(3.78 l). (Note: Do not overfill tank with solution.)

4.  Replace pump assembly (PUFPA-2) and tighten securely by 

twisting the pump handle clockwise.

5.  Turn pressure relief valve (PUF-PRV-2) clockwise 1/2 turn 

to return to the closed position.

6.  Pressurize the tank by pumping approximately 15 to 20 

times, depending on amount of solution in tank. (Note: 

The pressure relief valve will leak if the air pressure is too 

high. Do not overfill tank with air.)

7.  Once the desired pressure has been achieved, push the 

handle down and twist it clockwise to lock it in place.

8.  To start spraying, point the wand assembly at the area you 

wish to spray and squeeze the trigger handle to discharge 

spray.

After Use Instructions: 

1.  Ensure all air pressure is released from unit by twisting the 

pressure relief valve (PUF-PRV-2) clockwise 1/2 turn.

2.  It is recommended to always empty out remaining 

solution and run fresh water through the unit to rinse all 

parts thoroughly after each use and before storage.

Maintenance Instructions: 

Warning: Always depressurize unit before performing 

maintenance

.

To keep your unit operating properly, periodically perform the 

following maintenance procedures:

• 

Check the pump assembly (PUFPA-2) for wear and leaks.

• 

Check the suction tube (PUF-PST2) for debris and clean as 

needed.

• 

Inspect hose (SL48-P) for leaks or excessive wear.  

• 

Periodically lubricate the pump seal with a food safe 

lubricant.   To lubricate the pump seal, raise pump handle 

and apply 5 to 10 drops of food safe lubricant between 

pump and pump sleeve.  NEVER USE LUBRICANTS SUCH 

AS WD40.  