31
MY WARRANTY HAS EXPIRED
The manufacturer, Innovaplas, will continue to provide service for your spa even after your warranty has expired. You can contact the
manufacturer’s customer care center at 1-866-995-8646, extension 226.
DRAINAGE FREQUENCY
You should drain and refill your spa every one to three months depending on usage. You should also replace the filter cartridge and
wipe down the spa.
BLEEDING AIR FROM YOUR SPA
When draining and refilling your spa, air may enter the pump which will keep the water from flowing into it. Below are the steps to take
to bleed an air-locked pump:
1. Turn off the GFCI breaker
2. Open the access door to the equipment enclosure.
3. Loosen a heater union until you hear the trapped air escape.
4. Once water drips out in a continuous stream, hand tighten the union until the water stops leaking.
5. Turn on the GFCI breaker.
6. Turn on all pumps to make sure that the pump starts and that there are no leaks.
7. Put the access door back on.
TROUBLESHOOTING
F
igure
1.4 :
heater
union
;
loosen
up
to
bleed
air