3. Initial Setup

With the power off press and hold the button and turn the power on.  

The button must remain pressed to stay in setup mode.

Manual Zero

Keep holding the button down after the calibration year is shown in 

setup mode to initiate Manual-zero. 

Make sure there is no vacuum on the port.

The software version is 

shown eg. v5.0

Calibration month eg. October

Calibration year eg. 2018

The display will flash 0.0 five 

times before the zero starts.

When it stops flashing 

Manual-zero is completed.

Содержание DVG LH DR40-0080

Страница 1: ...DVG LH Dairy Vacuum Gauge USER MANUAL Part No DR51 0044 14...

Страница 2: ...ncluding interference that may cause undesired operation Declaration of Conformity Standards to which Conformity is Declared EN 61000 4 2 EN 61000 4 3 EN 61000 6 1 EN 61000 6 2 EN 61000 6 4 IEC 61326...

Страница 3: ...d hereby declare that the equipment specified above conforms to the above Directives and Standards Braham Basser Date 30 July 2010 Director InnovAg Pty Ltd Enclosure LCD Silicone tubing Metal fittings...

Страница 4: ......

Страница 5: ...11 6 Demonstration mode 12 7 Maintenance Calibration 13 8 Specifications 13 9 Warranty 14 All rights reserved No part of this manual may be reproduced transmitted stored in a retrieval system or tran...

Страница 6: ...Liner wear monitoring Continuous bar graph display of remaining liner life Display of remaining liner life in Manual reset of liner life remaining i e liners have been replaced 2 Installation Mount DV...

Страница 7: ...nual Zero Keep holding the button down after the calibration year is shown in setup mode to initiate Manual zero Make sure there is no vacuum on the port The software version is shown eg v5 0 Calibrat...

Страница 8: ...etup mode The screen will cycle through all combinations continuously Release the button when the desired setting combination is shown as described below Units kPa Liner milkings disabled Units kPa Li...

Страница 9: ...play the remaining liner life as percentage eg 75 3 Display Liner Life in Holding the button down will display the software version calibration month and calibration year The software version is shown...

Страница 10: ...g Liner Life counter should be reset to 100 99 9 Keep holding the Button down after FAST mode to initiate Liner reset mode Slow response to vacuum changes can be inconvenient when performing an equipm...

Страница 11: ...ING life in as above both on on life LINER LIFE DISPLAY LINER ICON LINER LIFE BAR GRAPH Milking Vacuum has been higher than 20kPa 5 9inHg for at least 20 mins Liner Life Remaining life based on 1200 o...

Страница 12: ...ode is useful to show how the DVG works without waiting the long times normally required for events to occur The following times change ITEM NORMAL DEMO Wait for vacuum to stabilise at start of milkin...

Страница 13: ...aintained mercury manometer can easily have an error of 0 5kPa If checking DVG be careful that the other meter you are using is reliably accurate and the vacuum is perfectly stable DVG can be returned...

Страница 14: ...t will be warranted under the terms of this Warranty for the remainder of the applicable Warranty period Repair may include the replacement of parts or components with functionally equivalent recondit...

Страница 15: ...ights With respect to Non excludable Rights innovAg s responsibility to the Purchaser where permitted is limited to the undertakings as stated in the clause headed WHAT WE WILL DO Subject to the above...

Страница 16: ...2018 InnovAg InnovAg Pty Ltd 37 328 Reserve Road Cheltenham Victoria 3192 Australia FreeCall within Australia 1800 061 167 61 3 9583 2832 sales innovag com www innovag com A C N 073 191 376 2018 Innov...

Отзывы: