Mounted on board the machine, it manages the motor with
fixed speed; it can only be installed on the SL and SLI versions
and can be connected to controls with an thermostat or any
other controls available on the market.
Place the control panel into its housing in the upper part of
the cooler-convector/cooler-radiator and fix it with the two
supplied screws (ref. A).
To install the connection box:
-
open the box (ref. B);
-
insert the lower lug into the special slot (ref. C) on the
side of the appliance;
-
hook the upper part of the box to the side (ref. D);
-
fix it with the two supplied screws (ref. E);
-
fix the earth wire to the cooler-convector/cooler-radiator
structure using the supplied screws (the minimum force
of about 2N must be used when screwing-up);
-
the 2 terminals of the LOCK clamp (ref. I) feature a
jumper that ensures the operation of the SLI and RSI
versions without microswitch.
For the other versions remove the jumper and connect
the two terminals from the grid safety microswitch. * ;
-
connect the rapid connector on the motor (FAN_COIL)
to that on the board;
-
make the electrical connections, order the wiring and fix
the wires using the 3 supplied clamps (ref. F);
-
close the box and fix with the 4 screws (ref. G);
-
mount the aesthetic side panel on the Cooler-convector/
cooler-radiator;
-
tighten the upper screw on the control panel;
*
For versions with hydraulic connections on the right
refer to the relevant paragraph.
BB0642
Mounting and connecting the fan control for remote adjustment BB0642
Mounting
The LED (ref. A) is off if input CV is not closed (stand-by
condition).
It is switched on upon closure of contact CV and signals
standard operation.
It emits a single flash + pause for fan stop alarm due to
unsuitable water (with H2 water probe connected).
2 f pause for motor alarm (for example, jamming due
to foreign bodies, fault in the rotation sensor, activation of the
protective microswitch due to the filter cleaning operation).
3 f pause for water probe alarm disconnected or
faulty.