3.4 Turning Meter Off
The meter will turn on any time the
START
button is pressed. The
meter can be turned off in two ways:
1. The meter can be shut off by pressing and holding the
START
button for several seconds (about 3 seconds). As soon as the
LCD goes blank, release the START button.
2. The meter will automatically shut off after 90 seconds of
inactivity. This means that the user does not have to shut off
the meter after use since it will eventually shut itself off.
3.5 Installing New Batteries
(use N size 1.5 volt only)
The batteries are housed
under the black cap on the top
of the meter. This black cap
can be removed by pulling it
straight up while twisting
slightly. The cap is just a
press fit onto the meter. The
meter requires two (2) N size
alkaline batteries which are
available at any drug store. Place both new batteries in the battery
holder following the polarity indication marked on the holder (negative
ends towards the springs). Place the rubber retaining ring around the
batteries once they are in the holder as shown in Fig. 6. Then place
the battery holder back into the tube on the meter and replace the
black cap and press it firmly back onto the meter. When the meter’s
batteries need replacing, the meter will show “Lo b” on the LCD
display when the meter is turned on. If this message is displayed, the
batteries should be replaced as described above.
4.0 Troubleshooting
The Flow Meter measures the flow rate by measuring the time it takes
to fill the meter’s container. The rising water level is sensed by 3
electrodes in the meter. The meter will only function with fluids that
conduct electricity, such as water. In the case of distilled water, the
conductivity may be too low for proper meter operation. All tap water
will work very well with the meter. Any substance that coats or covers
the exposed metal on the electrodes will hinder their ability to sense
the water level. Care should be taken to rinse the meter inside and
out with clean tap water when measurements are complete.
Fig. 6
7
5.0 Warranty & Service
One Year Warranty
Innoquest, Inc. warrants this product to be free from defects in
materials and workmanship under normal use and service for a period
one (1) year from date of purchase. This warranty extends only to the
original purchaser and shall not apply to any product which, in
Innoquest’s sole opinion, has been subject to misuse, alteration,
abuse, or abnormal conditions of operation or handling. Innoquest’s
obligation under this warranty is limited to repair or replacement of the
product which is returned to Innoquest. Innoquest accepts no liability
for whatever damages may be caused by a malfunctioning product.
Repair & Service Policy
Product returned to Innoquest for repair or service must follow the
guidelines set forth as follows: Return of the product for warranty or
service repair will be the responsibility of the purchaser (Innoquest
does not pay inbound shipping charges). All returns must receive an
RMA number by
calling
Innoquest prior to return of the product. The
RMA number must be clearly marked on the outside of the shipping
carton. If the customer is returning product for non-warranty related
repair or service, a minimum charge will apply for accessing the
product’s repair needs and further work will not be completed without
the customer’s approval.
910
Hobe
Road
Woodstock, IL 60098
Toll Free: 800-637-1623
Phone: 815-337-8555
Fax: 815-337-8556
[email protected]
www.InnoquestInc.com
© 2012 Innoquest, Inc. USA P/N 23750 Rev. 2 (Revised 11/16/12)