background image

3

IR lens

(Lens extension for 

high installations)

Button

Signal LED

should face towards user

TECHNICAL SPECIFICATIONS

Battery lid

The Stove Alarm is a battery-

operated device. Use only new 

CR2302 button cell (watch type) 

batteries. To avoid damage or mal-

function, do not use other types.

 

Pull out the battery lid. Place the 

battery under the lid, and slide 

the lid back in. Make sure that 

“the plus side” comes upwards 

(towards the battery lid). The 

Stove Alarm makes a “beep” 

when the battery is inserted 

correctly. Replace the leaking 

battery immediately.

SGS1030  Stove Alarm 
•  Nature of supply: Battery operated 
 

(CR2302

 Button Cell, 

3V DC)

•  Sensor Dislocation Alarm
•  Adjustable sensitivity levels (learning)
•  Audible alarm signal min. 65 dB(A),  
  max. 80 dB(A) @ 40’’ (100cm)
•  Sensing distance (from the range top)
  18’’–32’’ (45–80cm) OTR/range hood installation 
•  Flame retardant and high heat resistant plastics, 
  UL recognition 94 V-0 
•  Wireless 315 MHz/10mW RF

•  Operating ambient temperature: 
 

32 °F to 95 °F ( 0 °C to 35 °C)

•  Intended transportation condition of control: 
 

14 °F to 131 °F (-10 °C to 55 °C)

 

Applied standards

FCC Rule Part: 15.231:2017 (Periodic operation in the band 
40.66-40.70 MHz and  above 70 MHz)
 IC Rule Part: RSS-210 Issue 9, 2017 and RSS-GEN Issue 5, 2018

U.S. Pat. Nos 10,051,993 and 10,347,112

Installation plate 

with adhesive tape

Stove Alarm

Содержание SGS1030

Страница 1: ...For indoor use only Do not use in a professional kitchen REFERENCE AND INSTALLATION MANUAL INNOHOME STOVE ALARM SGS1030 770 00090 A1...

Страница 2: ...it makes the use of the stove safer Never leave the stove unattended Always check compliance with local regulations For indoor use only Do not use in a professional kitchen Do not hold the Stove Alarm...

Страница 3: ...Stove Alarm Nature of supply Battery operated CR2302 Button Cell 3V DC Sensor Dislocation Alarm Adjustable sensitivity levels learning Audible alarm signal min 65 dB A max 80 dB A 40 100cm Sensing di...

Страница 4: ...tage indicating that it is not properly placed on the installa tion plate As this happens no further action is required If there is a metal mesh grease filter on the range hood make sure it is greasel...

Страница 5: ...n sensitivity configuration 3 4 5 Watch the movie https vimeo com 321503955 Setting sensitivity Watch the movie https vimeo com 321502592 Sensor installation DISTANCE FROM COOKER TO HEAT SENSOR COOKER...

Страница 6: ...beep at this stage indicating that it is not properly placed on the installa tion plate As this happens no further action is required If there is a metal mesh grease filter on the range hood make sure...

Страница 7: ...film on sensitivity configuration Watch the movie https vimeo com 321503955 Setting sensitivity Watch the movie https vimeo com 321502592 Sensor installation DISTANCE FROM COOKER TO HEAT SENSOR COOKE...

Страница 8: ...rm The Stove Alarm sounds an alert to danger If the alarm was triggered during normal cook ing press the button once while the pre alarm sounds The alarm is turned off and the sensitivity adjusts slig...

Страница 9: ...uation However it is important to check the Stove Alarm s function see the next sections ANSWER 2 Make sure that the Stove Alarm is correctly installed See page 5 and after ANSWER 3 It is possible to...

Страница 10: ...ity level it is important the process is not rushed Ensure the sensor button is pressed firmly down each time holding for a period of 1 second before releasing Ensure to pause for 1 second between eac...

Страница 11: ...4 Press and hold the button until the three beeps are heard Release If three beeps cannot be heard something went wrong Repeat from Step 1 Return the Stove Alarm to its installation plate and press th...

Страница 12: ...Subpart C of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including inte...