58
INNOCIGS EGRIP 2 LIGHT – ERROR MESSAGES & PROTECTIONS
Low Power Alarm:
Atomizer Low Alarm
Temperature Protection
Unit too hot
If the battery voltage drops below 3.1V, the device indicates
“Battery Low”
. If you continue to hold down the fire button, the unit
displays
“Battery Low Lock”
and switches itself off. Charge the battery again to unlock the device.
If the resistance of the coil is lower than 0.1 ohm in VW mode or 0.05 ohm in VT mode, the display will show
“Atomizer Low”
.
If the temperature of the atomizer coil is above the temperature you set in VT mode, the unit will display
“Temp Protection”
.
When the temperature of the device increases above 70°C, the power turns off and the display will read
“Device Too Hot”
.