6
©2000 - INLINE, INC VKM01 Video / Keyboard / Mouse Extender System Operation Manual - Preliminary 02/18/00
Operation
This section offers step-by-step instructions for operating the VKM01 Video / Keyboard /
Mouse Extender System.
1.
Turn the VKM03 Remote Module power switch on. The switch is located on the
back of the unit between the RJ45 CAT5 LINK and the IN9204-1 power adapter
connectors.
2.
Turn the CPU and the monitors on. Since the VKM02 Local Module derives power
directly from the computer, the unit automatically powers up when the CPU is turned
on.
3.
Both the VKM02 and VKM03 modules feature dual, front panel LED indicators
(labeled LOCAL and REMOTE). After power has been applied to both units, the red
LEDs will illuminate for about three seconds. The system is ready to be used when
the LEDs begin flashing.
4.
Operators gain control of the system when they move the mouse or commence using
the keyboard at either location. The system automatically senses which location has
control and the LEDs illuminate accordingly. If the operator at the local module has
control of the system, the LOCAL LEDs will illuminate on both the VKM02 and
VKM03. If the operator at the remote module has control of the system, the
REMOTE LEDs will illuminate on both units. The operator maintains control of the
system until their keyboard / mouse activities cease. At this point (after about three
seconds), the LEDs on both modules will begin flashing, indicating that the system is
available to either location. Regardless of which station is controlling the computer,
both the local and remote monitors will display the same data.
5.
The VGC control on the back of the VKM03 Remote Module allows the operator to
adjust the signal to achieve optimal video quality at various input resolutions and
with different CAT5 cable lengths. Turning the VGC pot clockwise increases the
cable compensation, while turning it counterclockwise will decrease the cable
compensation. Using the IN9333 adjustment tool provided, gently adjust the VGC so
that a good quality image is displayed. The VGC pot is recessed to increase
durability and help avoid accidental changes to the setting. Note: The entire rotation
range of the VGC control is just over 180 degrees, so care must be taken not to force
or over-rotate the pot.