background image

Installation and Safety Instructions

 

 

For Models without a Power Switch: 

The socket outlet shall be installed near the equipment and shall be accessible. 

 

 

For all Models: 

No serviceable parts inside the unit.  Refer service to a qualified technician. 

 

For Models with Internal or External Fuses: 

For continued protection against fire hazard, replace only with same type and rating of fuse. 

 
 

 

Instructions d’installation et de sécurité

 

 

Pour les modèles sans interrupteur de courant: 

La prise de courant d’alimentation sera installé près de l’équipement et sera accessible. 

 

 

Pour tout les modèles: 

Pas de composants à entretenir à l’intérieur.  Confiez toute réparation à un technicien qualifié. 

 

Pour les modèles équipés de fusibles internes ou externes: 

Afin d’éviter tout danger d’incendie, ne remplacer qu’avec le même type et la même valeur de fusible. 

 

 

Installations- und Sicherheitshinweise

 

 

Für Geräte ohne Netzschalter: 

Die Netzsteckdose soll in der Nähe des Gerätes installiert und frei zugänglich sein. 

 

 

Für alle Geräte: 

Keine Wartung innerhalb des Gerätes notwendig.  Reparaturen nur durch einen Fachmann! 

 

Für Geräte mit interner oder externer Sicherung: 

Für dauernden Schutz gegen Feuergefahr darf die Sicherung nur gegen eine andere gleichen Typs und gleicher Nennleistung 
ausgewechselt werden.

 

 

Instalacion E Instrucciones de Seguridad

 

 
Modelos Sin Interruptor:
 

La conexión debe ser instalada cerca del equipo y debe ser accesible. 

 

 

Para Todos Los Modelos: 

Dentro de la unidad , no hay partes para reparar.  Llame un tecnico calificado. 

 

Modelos con Fusibles Internos o Externos: 

Para prevenir un incendio, reemplace solo con el mismo tipo de fusible. 

 

 

CE COMPLIANCE 

All products exported to Europe by Inline, Inc. after January 1, 1997 have been tested and found to 
comply with EU Council Directive 89/336/EEC.  These devices conform to the following 
standards: 
 

 

EN50081-1 (1991),  EN55022 (1987) 

 

 

EN50082-1 (1992 and 1994), EN60950-92 

 

 

  

Shielded interconnect cables must be employed with this equipment to ensure compliance with 
the pertinent Electromagnetic Interference (EMI) and Electromagnetic Compatibility (EMC) 
standards governing this device.

 

 

 

 

FCC COMPLIANCE 

This device has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC rules.  These limits are designed to provide against harmful 
interference when equipment is operated in a commercial environment.  This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications.  Operation of 
equipment in a residential area is likely to cause harmful interference, in which case the user will be 
required to correct the interference at their own expense.

 

 

 

 

 

Содержание MSX1616

Страница 1: ...High Resolution Video Products A V System Integration Tools Interactive Training Systems MSX1 6 1 6 MSX1 6 1 6HR MATRIX SWITCHER 1 6 INPUT 1 6 OUTPUT MSX 1 6 1 6 MSX 1 6 1 6HR OPERATION MANUAL...

Страница 2: ...n Instalacion E Instrucciones de Seguridad Modelos Sin Interruptor La conexi n debe ser instalada cerca del equipo y debe ser accesible Para Todos Los Modelos Dentro de la unidad no hay partes para re...

Страница 3: ...ctions 9 DIP Switch Settings Standard 9 DIP Switch Settings Termination 10 Compatibility 12 Input 12 Output 12 Operation 15 Front Panel Controls 15 Front Panel Operation 16 Creating a Patch in Matrix...

Страница 4: ...v1 0 5 8 02 2002 INLINE INC Serial Commands 26 Addressing Commands 26 Set Up Commands 27 Level Commands 28 Switching Commands 29 Volume Commands 30 Auxiliary Commands 33 Preset Commands 35 Preset Lab...

Страница 5: ...dio Output Step 6 Select the serial communication protocol format for serial port 1 as required by the control system Set DIP switches in Switch Bank 1 according to the following chart Port 1 Serial F...

Страница 6: ...to blank any or all outputs CANCEL deletes unsaved configurations Functionality Creating new patches 1 Press the button of the desired input device 2 Press the button s of the output s where you want...

Страница 7: ...he switcher using RS 232 RS 422 or RS 485 serial commands Offers fast communication speed individual unit addresses and command buffering New Serial Control Protocol for programming serial commands Er...

Страница 8: ...auxiliary serial commands Blank Front Panel Versions are available at a lower cost MSX1616 model Numbers 16 x 16 Matrix Switcher 160 MHz With Faceplate Without Faceplate RGB Component Video MSX1616 1...

Страница 9: ...he equipment rack 2 Align the mounting holes of the unit with those of the rack 3 Fasten the switcher to the rack using the machine screws included with the rack Device Connections All connections inc...

Страница 10: ...s are Composite S Video Component RGB Video The types of signals that the switcher can receive on the H C and V input connectors are TTL level sync info Note Video signals do not pass on sync channels...

Страница 11: ...am Full Duplex RS 422 485 Connection Diagram Half Duplex RS 485 Connection Diagram DIP Switch Settings Standard DIP switch settings change according to the standard used Higher standards require a dif...

Страница 12: ...F Switch 1 Position 4 Receive termination OFF ON OFF ON OFF Switch 1 Position 5 Transmit termination OFF OFF OFF ON OFF Switch 1 Position 6 PORT 2 RS232 485 select ON ON ON ON OFF Switch 2 Position 1...

Страница 13: ...11 2002 INLINE INC MSX1616 OPERATION MANUAL v1 0 5 8 02 MSX1616 DIP switch ON position MSX3216 DIP switch ON position...

Страница 14: ...u 32 possible input output configurations The MSX1616 has analog audio follow video and breakaway capability All analog audio inputs are compatible with balanced and unbalanced line level signals from...

Страница 15: ...13 2002 INLINE INC MSX1616 OPERATION MANUAL v1 0 5 8 02...

Страница 16: ...14 MSX1616 OPERATION MANUAL v1 0 5 8 02 2002 INLINE INC...

Страница 17: ...ny new settings VOLUME Adjusts volume of selected audio output or input TAKE Completes a patch and saves the switch configuration into non volatile memory CANCEL Deletes any unsaved configuration term...

Страница 18: ...ss the number s of the output s where you want the input signal sent Result The LED indicator blinks The connection does not yet exist 3 Press TAKE Result The switcher makes the patches stores the inf...

Страница 19: ...glows Press CANCEL to exit Preview mode If you need to change any patches exit this feature and follow the Matrix Mode instructions above or press the LCD buttons pointing to Q or 2XW Recalling Prese...

Страница 20: ...G 2 3UHVV 17 5 WR 5HVHW 3UHVV 0 18 WR LW UDVHV QWLUH RQILJ 7DNHV WZR PLQXWHV 3UHVV 17 5 WR 5HVHW 3UHVV 0 18 WR LW XUUHQW HYHO 5 9 3UHYLHZ Q 2XW 6HOHFW HYHO HYHO 5 9 HYHO 5 9 HYHO XGLR HYHO 1R RDUGV HY...

Страница 21: ...e LCD menu functions 1 Press MENU button until XUUHQW HYHO displays in the LCD 2 Press the soft key pointing to Q or 2XW on the LCD Result The LCD shows QSXW and 2XWSXW or the last output or input num...

Страница 22: ...navigation buttons to select an input Then use the VOLUME buttons to adjust the level Select 2XWSXW WWHQXDWLRQ to perform the same function as the VOLUME buttons on the front panel Use the left and r...

Страница 23: ...ect the soft key pointing to 6HULDO 6HWXS Result 6HULDO 3RUW 6HWXS displays in the LCD 4 Select the soft key pointing to the serial port you want to set up Result The LCD screen for that port displays...

Страница 24: ...g to XOO 5HVHW Result The switcher resets the RS232 serial port opens all input output patches resets all volume levels removes any address given to the unit and clears all saved presets and labels Th...

Страница 25: ...el or via serial control using the CPxbpsfd serial command Other adjustable parameters for port 1 include flow control none or Xon Xoff and duplex full or half Parity data bits and stop bits are prede...

Страница 26: ...G menu option on the LCD on the front panel or via serial control using the CPxbpsfd command Flow control and duplex parameters are predefined and have no affect on ports 2 or 3 The factory default co...

Страница 27: ...25 2002 INLINE INC MSX1616 OPERATION MANUAL v1 0 5 8 02 Serial Port Pin outs RS 232 Connection Diagram Full Duplex RS 422 485 Connection Diagram Half Duplex RS 485 Connection Diagram...

Страница 28: ...unit must be between 01 and 98 Address 00 is a broadcast address and all units on the buss will perform the action commanded however the unit will not issue any responses To open communications to an...

Страница 29: ...e flow control 1 to enable flow control o d 0 for full duplex and 1 for half duplex DFLTx Performs factory reset The partial reset will default I O configurations volume levels and serial set up but d...

Страница 30: ...can consist of combinations of R G B HV and audio boards You can access six assignable levels via the front panel or serial control For commands that use level designators see Switching Commands and...

Страница 31: ...m nn oo pp Preloads an I O configuration for a specific level Each output has a two character placeholder for an input assignment to that output Inserting 00 will blank the output A TAKE command must...

Страница 32: ...able mute 1 to enable mute o x to request current state o x left blank to toggle current state MUTE Toggle mute un mute all outputs MUTE Queries all mutes VOL Increase volume for all outputs VOL Decre...

Страница 33: ...lume level for a specific output Where o oo 01 16 for output o x plus sign to increment output volume o x minus sign to decrement output volume o x to return output volume to factory default 0 dB o x...

Страница 34: ...tput 1 o b 0 to disable 1 to enable for output 2 o c 0 to disable 1 to enable for output 3 o d 0 to disable 1 to enable for output 4 o e 0 to disable 1 to enable for output 5 o f 0 to disable 1 to ena...

Страница 35: ...and to execute changes Where o aaa 550 to 90 for output 1 o bbb 550 to 90 for output 2 o ccc 550 to 90 for output 3 o ddd 550 to 90 for output 4 o eee 550 to 90 for output 5 o fff 550 to 90 for output...

Страница 36: ...cde PCLpIii Loads ASCII command string to an input up to 60 characters Where o p 2 for port 2 3 for port 3 o ii 01 16 for input o abcdef hex string to be stored o abcdef queries current label Note Whe...

Страница 37: ...for port 2 3 for port 3 o oo 01 16 for output PCCpPmmm Forces command string loaded to a specific preset to be sent Where o p 2 for port 2 3 for port 3 o mmm 001 256 for preset PCPDpxx Sets projector...

Страница 38: ...preset to strictly send out command strings and to have no effect on current I O configuration Where o xxx 001 256 Preset Label Commands The MSX1616 has the ability to store preset label commands up...

Страница 39: ...37 2002 INLINE INC MSX1616 OPERATION MANUAL v1 0 5 8 02...

Страница 40: ...uding without limitation any implied warranty or merchantability or fitness for any particular purpose all of which are expressly disclaimed The information in this manual has been carefully checked a...

Отзывы: