background image

INSTALLATION TIPS 

Mount pig sensor with plastic tie straps and calibrate with Installation and Operations instructions provided with shipment  

Launching PLR 1 

Pigs with magnets in each end have a null area in the center where magnetic detection is weak.  Position MPS2 sensor to detect  either 
the leading or trailing end section of the pig to avoid the null area. 

Launching PLR 2 

Sensor mounting on Launching PLR is best located to detect the magnet in the trailing end of the pig.  The normal position is at the end 
of the larger diameter relax chamber as shown on Launching PLR1 photo to the right.  An alternate position is shown on Launching 
PLR2 photo.  This position is further back toward the mounting end of the PLR and on the flat surface as close to the larger diameter 
relax chamber as possible.  

Relax Receiver-Stop PLR 1 

Mounting position on Relax Receiver-Stop PLR is normally best located to detect the leading end pig magnet as the pig rests against 
the internal pig bar stop (not visible).  The pig bar stop is located just in front of the return air fitting as shown on photo Relax Receiver-
Stop PLR1 to the right.  An alternate mounting position is to detect the trailing end pig magnet as shown in Relax Receiver-Stop PLR2 
photo 

Relax Receiver-Stop PLR 2 

Inline Services, LLC. 27731 Commercial Park Rd., Tomball, TX 77375 | 281.401.8142 / 888.973.0079

[email protected] | inlineservices.com

pg 2 of 2

Отзывы: