Installation and Safety Instructions

For Models without a Power Switch:

The socket outlet shall be installed near the equipment and shall be accessible.

For Models with 110 / 220V Power Selector:

Caution:  Before applying power to this unit, the voltage selector must be set to the appropriate setting to match local A/C line
voltage.  Improper setting of the voltage selector may cause damage to the unit and create a potential fire hazard.

The voltage selector is a round switch located next to the A/C power input connector which looks
like this:

 

Using a straight slot screwdriver or small coin, rotate the selector to the correct position so that

the arrow lines up with 110 or 220 as appropriate for local power line voltage as indicated in the
chart below:

Local A/C Voltage

Voltage Selector Setting

110 ~ 120 VAC

110

220 ~ 240 VAC

220

For all Models:

No serviceable parts inside the unit.  Refer service to a qualified technician.

For Models with Internal or External Fuses:

For continued protection against fire hazard, replace only with same type and rating of fuse.

For IN2001 / IN3234 / IN3236 / IN3502 / IN3504 / IN3506 / IN3562 / IN3564 / IN3566 / IN3572 / IN3574 / IN3576:

Caution:  Double pole / neutral fusing.

For all Models with Integral Lithium Battery:

Caution:  Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by
the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

Instructions d’installation et de sécurité

Pour les modèles sans interrupteur de courant:

La prise de courant d’alimentation sera installé près de l’équipement et sera accessible.

Pour les modèles avec un sélecteur d’alimentation 110V/220V:

Attention:  Avant de connecter l’appareil au circuit d’alimentation, le sélecteur de courant doit être positionné sur la sélection
appropriée correspondant au voltage du circuit de courant alternatif local.  Une mauvaise sélection peut engendrer des
dommages à l’appareil et créer un danger d’incendie.

Le sélecteur d’alimentation est un commutateur rond positionné près du connecteur
d’alimentation.  Il se représente comme suit:

A l’aide d’un tourne-vis plat ou d’une pièce de monnaie, le sélecteur peut être tourné dans la
position adéquate en veillaut que la flèche corresponde avec 110 ou 220, en fonction de la
valeur du circuit de courant local.  (Voir tableau ci-dessous)

Circuit local AC

Position Sélecteur

110 ~ 120 VAC

110

220 ~ 240 VAC

220

Pour tout les modèles:

Pas de composants à entretenir à l’intérieur.  Confiez toute réparation à un technicien qualifié.

Pour les modèles équipés de fusibles internes ou externes:

Afin d’éviter tout danger d’incendie, ne remplacer qu’avec le même type et la même valeur de fusible.

Pour IN2001 / IN3234 / IN3236 / IN3502 / IN3504 / IN3506 / IN3562 / IN3564 / IN3566 / IN3572 / IN3574 / IN3576:

Attention:  Double pôle / fusible au neutre.

Pour tout les modèles avec une batterie au lithium interne:

Attention:  Danger d’explosion si la batterie est incorrectement remplacée.  Ne remplacez la batterie qu’avec le même modèle,
ou avec un modèle recommandé par le constructeur.  Traitez les batteries usagées selon les instructions du fabricant, ou selon
les normes écologiques en viguer.

Содержание IN3055

Страница 1: ...Operation Manual IN3055 1x4 VGA Distribution Amplifier ...

Страница 2: ...ité Pour les modèles sans interrupteur de courant La prise de courant d alimentation sera installé près de l équipement et sera accessible Pour les modèles avec un sélecteur d alimentation 110V 220V Attention Avant de connecter l appareil au circuit d alimentation le sélecteur de courant doit être positionné sur la sélection appropriée correspondant au voltage du circuit de courant alternatif loca...

Страница 3: ... durch den gleichen oder entsprechenden Typ wie vom Hersteller empfohlen Entsorgung verbrauchter Batterien nur nach den Anweisungen des Herstellers Instalacion E Instrucciones de Seguridad Modelos Sin Interruptor La conexión debe ser instalada cerca del equipo y debe ser accesible Modelos con Selector de Voltaje de 110 220V Precaución Antes de operar esta unidad el selector de voltaje debe instala...

Страница 4: ...overning this device FCC COMPLIANCE This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide against harmful interference when equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance ...

Страница 5: ...LITY The IN3055 VGA distribution amplifier operates with analog video input from a wide variety of IBM and compatible computer video signal formats including VGA SVGA XGA and 8514A Input signals to the IN3055 must be in the RGBHV format and provided on a 15 pin HD connector OUTPUT COMPATIBILITY The IN3055 offers four buffered video output signals in the same format and using the same connector as ...

Страница 6: ...5 has three internal jumpers which affect the termination of the Red Green and Blue input signals In normal installations the IN9041 loop through input cable included with the unit should be used on the input connector and either a local monitor or termination plug is attached to the female side of the loop through cable Certain applications may call for the IN3055 to be installed without the IN90...

Страница 7: ...NPUT Local Monitor Computer CPU IN9041 Input Loop Cable IN3055 Data Projector Power Supply 12V 500 mA IN8000 Series Cables RGBHV Input IN9045 Application Diagram IN3055 Multi Sync Monitor VGA Monitor VGA Monitor ...

Страница 8: ...format as the input signal with sync polarities preserved Dimensions Power 9V 500 mA DC Size Height 1 0 Width 7 7 Depth 4 0 Shipping Weight 3 lb Parts Accessories Included IN3055 1 x 4 VGA Distribution Amplifier IN9041 Loop Through Input Cable 9V 500 mA Power Supply Operations Manual Optional Accessories Input Output Cables IN8000 Series High Resolution Mini Coax Cables w 15 Pin HD Connectors avai...

Страница 9: ...or a very long cable on the local monitor may cause this problem The IN3055 must be located immediately adjacent to the source computer Do not attempt to lengthen the input cable The output image of the IN3055 is too bright blooming Solution There needs to be a termination on the loop through output Use a local monitor or an IN9031 termination plug to provide the necessary 75 ohm termination When ...

Страница 10: ...ding without limitation any implied warranty or merchantibility or fitness for any particular purpose all of which are expressly disclaimed The information in this manual has been carefully checked and is believed to be accurate However Inline Inc assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Inline Inc be liable for direct indirect special in...