background image

PID Temperature Controller 

 

ITC-106 

User Manual 

Version 1.0 

 

 

 
 

 

 

Inkbird Tech. Co., Ltd. 

 
 
 
 
 
 
Copyright 

Copyright

©

  2016  Inkbird Tech.  Co.,  Ltd.  All  rights  reserved.  No  part  of  this  document  may be  reproduced 

without prior written permission. 
 

Disclaimer 

Inkbird  has  made  every  effort  to  ensure  that  the  information  contained  in  this  document  is  accurate  and 
complete;  however,  the  contents  of  this  document  are  subject  to  revision  without  notice.    Please  contact 
Inkbird to ensure you have the latest version of this document. 

 

http://waterheatertimer.org/Add-another-thermostat-to-gas-or-electric-water-heater.html#PID

Содержание ITC-106

Страница 1: ...prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete however the contents of this document are subject...

Страница 2: ...nel Instruction 6 6 Setting Parameters 7 6 1 Sensor Type and Measuring Range 7 6 2 Operation Guide 7 6 21 Boot screen display 7 6 22 Enter the settings menu 7 6 23 Sensor Input Type Setting 8 6 24 Out...

Страница 3: ...ric shock fire or malfunction Do not use the product where subject to flammable or explosive gas Otherwise injury from explosion may occasionally occur Never disassemble modify or repair the product o...

Страница 4: ...ccuracy 0 2 FS 0 1 C F 1000 C F 1 C F 1000 C F Sampling Period 0 5 second Temperature Compensation 0 50 C 32 122 F Control Output Relay Output AC 250V 3A resistive load Voltage Output for driving SSR...

Страница 5: ...when there are two or more temperature controllers installed 4 Wiring Diagram 2 wires sensor 3 wires sensor Thermocouple Output Relay Output Voltage Power Connection 9 and 10 terminals are for power...

Страница 6: ...rapidly by keeping press this button DOWN Button when setting the value pressing the down button can be decrease the value that would be reduced rapidly by keeping press this button SHIFT Button when...

Страница 7: ...750 F E 0 1000 C 0 1800 F J 0 1000 C 0 1800 F B 0 1800 C 0 3200 F N 0 1000 C 0 1800 F Remarks The faulty input sensor is the K type If select the wrong input sensor the measuring temperature will be i...

Страница 8: ...and activate the alarm The exceeding temperature value is related to the heating system but it will return to normal after finished the self tuning If the temperature control requirement is undemandin...

Страница 9: ...ITC 106 User Manual Inkbird Tech Co Ltd www ink bird com 9...

Страница 10: ...ndition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or...