Содержание IVC-001W

Страница 1: ...130x160mm...

Страница 2: ...Smart Fan Controller Inline Duct Fan IVC 001W w A RRANT Y VOID IF SEAL BROKEN...

Страница 3: ......

Страница 4: ...tions 06 Automatic Control Mode Instructions CONTENTS 01 01 02 03 03 04 07 Manual Control Mode Instructions 09 Shutdown Mode 10 Lock Mode 11 ECO Mode 12 Parameter Factory Setting 13 Inline Duct Fan In...

Страница 5: ...01 Overview 02 Features Specifications Shutdown maximal tolerance Relative Humidity RH typical tolerance 8 RH RH 6 4 2 0 0 10 20 30 40 50 60 70 80 90 100 1...

Страница 6: ...ROLLER X1 SENSOR PROBE X1 MACHINE SCREWS WALL MOUNT X2 WOOD SCREWS WALL MOUNT X2 WOOD SCREWS WALL HANG X2 1 5 1 0 0 5 0 0 40 20 0 20 40 60 80 100 120 maximal tolerance typical tolerance T INLINE DUCT...

Страница 7: ...04 INKBIRD App 05 Smart Controller Instructions P1 P2 WORK1 WORK2 3...

Страница 8: ...hip between the current temperature and humidity and the trigger target temperature and humidity How to set the fan to run at a fan speed of 10 to keep the temperature at 81 0 to 82 0 and the humidity...

Страница 9: ...djust the low temperature trigger value to 81 0 Step2 Press and hold the button for 2 seconds to enter the setting mode or press or button to enter the quick setting mode in which SETTING is displayed...

Страница 10: ...LOW TEMP ALARM TEMP CALIBRATION HIGH HUMID ALARMDIFF HUMID VALUE LOW HUMID ALARM HUMID CALIBRATION SETTING HIGH TEMP ALARM DIFF TEMP VALUE LOW TEMP ALARM TEMP CALIBRATION HIGH HUMID ALARMDIFF HUMID V...

Страница 11: ...on for 2 seconds to enter the setting mode Press the button to select the high temperature trigger value HIGH TEMP is displayed and the corresponding parameter flashes Press both and buttons simultane...

Страница 12: ...s Note that at least one trigger function should remain on How to set temperature unit temperature alarm value humidity alarm value calibration value SETTING SETTING SETTING SETTING SETTING SETTING HI...

Страница 13: ...ual Control Mode Instructions Step1 Press the button to select the manual mode in which the symbol is displayed The fan will continuously run at the set fan speed from 0 10 and the running time regard...

Страница 14: ...d 7 Duration 1hrs Start at 12 00 Speed 10 Duration 3hrs Start at 17 00 Speed 9 Duration 3hrs Start at 5 00 Speed 7 Duration 2hrs Start at 8 00 Speed 10 Duration 3hrs Start at 12 00 Speed 10 Duration 3...

Страница 15: ...select the day to be set Here we choose Monday as an example Step4 Press the button to enter the setting of active time segments in which START TIME is displayed Press the or button to adjust the sta...

Страница 16: ...return to Step 3 and set the running state for other days Step9 Repeat steps 3 to 8 to set the running state parameters for Wednesday Friday and Saturday Step10 Press and hold the button for 2 seconds...

Страница 17: ...is displayed 11 ECO Mode In the power off state press and hold the button for 2 seconds to enter the setting of backlight brightness Press the or button to adjust the brightness percentage After 30 s...

Страница 18: ...13 Duct Fan Instructions DC Connect Wire 2 4m length 26AWG AC Power Cord 1 8m length 18AWG 14 Bottom cover Screw Power cover Butt plate Frame Hoops Duct A Duct Duct B Impelle 150 ALRFLOW...

Страница 19: ...of the flange bracket to mark the position to be mounted Pay attention to the direction of intake exhaust during installation referring to the instructions for intake exhaust Step4 Drill four holes a...

Страница 20: ...airflow arrow points in the desired direction Step7 Put the wind circle back on the intake flange and reposition the flange on the appropriate metal clips Step8 Move the power supply chassis back onto...

Страница 21: ...to secure the fan Step10 When installing the duct use the included duct clamps to secure it to either end of the duct fan making sure it is tightly sealed Use a flat head screwdriver to tighten the du...

Страница 22: ...fans or openings without fans must be placed in the bottom corners of the growing space and exhaust fans must be hung as shown below or mounted in the corresponding highest corners Make sure the airfl...

Страница 23: ...able length and the probe length Step2 Drill 2 holes at the marked locations Step3 If you need plastic expansion tubes insert the included 2 expansion tubes into the drilled holes and fix them in the...

Страница 24: ...the rope and put it into the tie bracket Step6 Insert the probe of the duct fan into the WORK1 WORK2 port of the controller Step7 Insert the temperature and humidity sensor probe into the P1 P2 port o...

Страница 25: ...s shown below Step1 Remove the power supply chassis from the flange See steps 1 and 2 in the installation instructions on how to remove the power supply chassis Step2 Use a wet cloth to remove dust an...

Страница 26: ...e undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea...

Страница 27: ...ment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20cm between the radiator your bod...

Страница 28: ...Temp Alarm Low temperature alarm value 40 100 40 212 or OFF disable low temperature alarm 40 0 40 0 Low Temp Alarm Temperature calibration value 4 9 4 9 9 9 9 9 0 0 0 0 Temp Calibration Low humidity t...