InisBofin Insert Boiler Multi-fuel Stove
19
Fig 10
The minimum depth of the recess
for the stove from the front face
should be 390mm. In most cases
this will require that the removal
of the fireback and the removal of
loose material. The distance from
the face of the fireplace to the
centre of the flue should be
checked to verify it is between
230mm and 330mm. Please ensure
that the stove in the recess sits
flat with the hearth.
Stove Fitting
There are two main methods of
connecting the stove to the
chimney. Method 1 is to use a
closure pipe adaptor section and
an extension piece. Method 2 is to
line the chimney with a suitable
6” liner for solid fuel and
connecting to the stove with a
solid section connector.
Method 1.
The fire surround will usually
need to be removed to fit the
stove and facilitate plumbing of
the stove. To aid rapid heating of
the water it may be beneficial to
place some fibre glass around the
boiler of the stove when
installing the stove. The closure
pipe adaptor section of flue
should have an offset built in to
allow for the difference in depth
from the front face of the
fireplace to the flue outlet on
the stove. Once the closure pipe
adaptor has been put in the