background image

10

Trouble shooting

OTT100H

5

TROUBLE SHOOTING

6

MAINTENANCE AND

PERIODIC CHECKS

Keep the lens clean to guarantee proper operation of the detector. 
A lens which is not perfectly clean may cause detection problems and/or problems

to the anti-mask function.
The cleaning must be done when necessary or when clearly dirty.

CLEANING 

PROCEDURE

Clean the lid and the lens with a cloth dampened with water.
Wipe with a dry cloth.

ATTENTION!

Do not use chlorine-based or abrasive products or alcohol to remove particularly

noticeable dirt.

7

DISPOSAL AND

SCRAPPING

DISMANTLING

1.

Unscrew the screws that fasten the front lid and remove it.

2.

Disconnect the detector; disconnect all the terminals on the terminal block.

3.

Divide the parts by type and dispose of them in accordance with applicable

laws.

ATTENTION!

Do not dispose of the components or any other product material in the

environment.

Seek the assistance of companies authorised to dispose of and recycle waste

materials.

Table 11: Possible solutions

Trouble

Solution

LEDs fail to switch on

Check wiring connection.

 Check the presence of current and if the voltage is between 9.5 and 16 V.

Make sure that DIP switch 6 is set to OFF.

False alarms

The detector is not perpendicular to the ground.

Check if the lower detection area is wider than your planning.
Check if there are objects in movement in the detection area.

MW adjustment is set at maximum level.

No detection, sometimes

The lower PIR is not properly adjusted.

MW adjustment is set at minimum level.

Continuous   alarms   of 

MASK output

Medium-sized obstacles close to the detector.

Open the cover, disconnect the detector (wait about 5 seconds), re-power and close 

the cover immediately (within 10 seconds), go out of range for 4 minutes.

Red LED blinking

 Verify that the detector’s power supply.

Содержание OTT100H

Страница 1: ...1 Installation and programming manual OTT100H Triple technology detector for outdoor use Installation and programming manual ...

Страница 2: ...s that the product must be disposed of correctly at the end of its working life and should never be disposed of together with general household waste The user therefore must take the equipment that has reached the end of its working life to the appropriate civic amenities site designated to the differentiated collection of electrical and electronic waste As an alternative to the autonomous managem...

Страница 3: ... Description of the product Triple technology detector for outdoor use Two PIR and one microwave MW programmable sensors MW frequency 24GHz Low consumption infrared sensors double element with UV filter Programmable infrared sensitivity Low PIR beam precision adjustment patented system AND OR selectable function Mechanism for horizontal coverage adjustment UV rays resistant Fresnel lens UV resista...

Страница 4: ... levels active IR IP protection degree IP44 Security grade 3 Environmental class IV Working temperature from 25 to 55 C Dimensions 189x81x70 mm Weight with wall fixing bracket 370g Table 2 Mechanical parts description A U shaped bracket B Stainless steel wall fixing bracket C Electronic holder D Cover with Fresnel lens E Lower PIR range adjustment knob F Anti tamper microswitch G Electronics and s...

Страница 5: ...arately Table 3 Electronic part description L Terminal board for wire connection M Red LED 1 for general alarm N Yellow LED 2 for MW O Green LED 3 for higher PIR detec tion P Green LED 4 for lower PIR detec tion Q Microwave sensitivity adjustment trimmer R Higher infrared sensor PIR 1 S Lower infrared sensor PIR 2 T DIP switches U Anti masking LED V PIR 2 marked positions Table 4 Terminal board PO...

Страница 6: ...3 V Each position corresponds to a distance These distances are reached when the detector is installed at about 120cm height If the object in motion is very large for example a car there is possibility that the detector can detect its presence even if it s farther than 18 m 2 2 Operating principles The detector works on the combined action of two PIRs and a microwave sensors The figures below show...

Страница 7: ...e anti masking channel Anti masking sensitivity can be adjusted trough the DIP switch 5 table 3 T OFF low sensitivity ON high sensitivity Follow the procedure below 1 Make the connections to the detector terminal box leaving the DIP switch 5 set to OFF 2 Once powered close the cover and run all the detection tests required 3 Open the cover and set the anti masking sensitivity via the DIP switch 5 ...

Страница 8: ...ection area any medium size animal can walk it is suggested to choose carefully the installation height in order to avoid false alarms Installation height must be between 1 m and 1 30 m not tilted ground Note The maximum coverage range 18m is reached when the detector is installed at about 120cm height Do not obscure partially or completely the detector s field of view COVERAGE TESTS Once the dete...

Страница 9: ...ions a single sensor adjustment system has been implemented In the tables below are shown the DIP switch configurations table 3 T If the detector is set in triple AND DIP 3 and DIP 4 in OFF position configuration the maximum distance of detection is the one setted through the Adjustment of the PIR2 Table 8 Infrared sensitivity adjustment DIP 1 OFF ON DIP 2 OFF High sensitivity Medium high sensitiv...

Страница 10: ...ENTION Do not dispose of the components or any other product material in the environment Seek the assistance of companies authorised to dispose of and recycle waste materials Table 11 Possible solutions Trouble Solution LEDs fail to switch on Check wiring connection Check the presence of current and if the voltage is between 9 5 and 16 V Make sure that DIP switch 6 is set to OFF False alarms The d...

Страница 11: ...ICS S R L ovime izjavljuje da je radijska oprema tipa OTT100H u skladu s Direktivom 2014 53 EU Cjeloviti tekst EU izjave o sukladnosti dostupan je na sljedeüoj internetskoj adresi www inim biz HU INIM ELECTRONICS S R L igazolja hogy a OTT100H típusú rádióberendezés megfelel a 2014 53 EU irányelvnek Az EU megfelelĘségi nyilatkozat teljes szövege elérhetĘ a következĘ internetes címen www inim biz LT...

Страница 12: ...12 Simplified EU Declaration of Conformity OTT100H Centobuchi via Dei Lavoratori 10 63076 Monteprandone AP Italy Tel 39 0735 705007 _ Fax 39 0735 704912 info inim biz _ www inim biz ...

Отзывы: