Dialup Number--- default: *99***1#, provided by local mobile operator.
APN/Username/Password --- provided by local mobile operator
PPP Heartbeat Interval --- the heartbeat to keep link alive
Redial Interval --- when ppp dialup failed, after this interval, InDTU300 will redial
MAX Retries --- after MAX Retries and no dialup successful, InDTU300 will reboot
6)
Click “
Data Center
” to configure the details of where InDTU300 connecting central site.
DTU No. --- The Number is for identifying InDTU(only for DC protocol).
Center IP --- User
’
s data center IP address (must be a static IP, if you have DNS only, just set it blank and
turn to DNS).
Port --- User
’
s data center server
’
s port.
DNS --- if your center has only DNS, you can set DNS to let InDTU access to data center.
Protocols --- TCP/UDP client, Modbus Bridge. For Kingview SCADA, you can also set DC UDP protocols.
Heartbeat Interval --- after this interval, InDTU will send a heartbeat to detect whether the server is reachable.