manufacturing/testing of electronic assemblies. The test fixture is connected to an existing test 

system. The electronic assemblies to be tested are connected within the test fixture and are then 

tested or programmed. An replacement kit (ATS) suitable for the electronics to be tested is in

-

stalled in the test fixture. The test fixture must be operated only with original Ingun ATSs.

5)

Liability in the event of misuse

INGUN assumes no liability for damages caused due to non-compliance with the operating in

-

structions, or a lack of testing to ensure that of the test adapter is in a technically perfect and safe 

condition.

6)

Commissioning the test fixture

Before initial connection to the test system, check interface compatibility thoroughly, paying par

-

ticular attention to the pinout for the test system.

7)

Commissioning the replacement set (ATS)

We recommend checking the contacts on the electronic assembly beforehand. When commis

-

sioning the ATS, ensure that all positions on the retention clamp have been verified as having ad

-

equate clearance to the components.

IMPORTANT 

Risk of component damage!

Due to positional tolerances, retention clamps may come into contact with components or 

press down on them and damage the test specimen.

Check all retention clamp positions to verify they have adequate clearance!

If clearance is insufficient, use retention clamps with a smaller diameter, or alternatively 

readjust/remove the retention clamps.

8)

Operation – ATS installation/removal (see Fig. 2)

Before installing the replacement kit into the test fixture, ensure that both replacement parts (probe 

plate unit and pressure frame unit) match both each other and the test specimen.

1) Insert the probe plate unit into the lower part of the test fixture from above

2) Place the pressure frame unit into the opened frame

3) Place the front part of the frame into the mounting bracket

4+5) Tighten the fixing screws

9)

Operation – testing (see Fig. 3)

The contacting stroke is generated by the operator by pushing down the pressure frame.

1) Insert the electronic assembly to be test in the correct position

2) Close test fixture (A)

3) Begin test and wait for test to end

4) Open test fixture (B) and (C)

5) remove tested electronic assembly

10) Maintenance – test probe inspection/replacement

The spring-loaded test probes are subject to very different loads. A reliable signal transmission is 

possible only with fully functional test probes. Conditions for a good quality of contact are:

no dirt on the contact head

no excessive wear of the tips on the contact head

no drag marks on the piston of the test probe

no abrasion dust below the test probe

tight fit of the test probe in the receptacle

Содержание MA 160

Страница 1: ...DE EN User manual Manual Test Fixtures MA 160...

Страница 2: ...1 DE EN Deutsch 2 English 6...

Страница 3: ...Deutsch INGUN Irrt mer und technische nderungen vorbehalten 2 Deutsch INGUN Irrt mer und technische nderungen vorbehalten...

Страница 4: ...ung Funktionskleinspannung mit sicherer Trennung betreiben Die auf dem Typenschild angegebene zul ssige Spannung nicht berschreiten VORSICHT Verletzung durch Durchstich oder Einstich Mechanische Gef h...

Страница 5: ...len berpr ft werden ACHTUNG M gliche Bauteilbesch digung Aufgrund von Positionstoleranzen k nnen Niederhalterstempel die Bauteile ber hren oder auf diesen aufsitzen und den Pr fling besch digen Alle P...

Страница 6: ...Technische Daten 12 Au erbetriebnahme 12 1 Lagern Den Pr fadapter nicht ungesch tzt im Freien oder in feuchter Umgebung aufbewahren Umgebungstemperatur 10 C bis 75 C Luftfeuchtigkeit 85 Kondenswasserb...

Страница 7: ...English INGUN mistakes and technical changes reserved 6 English INGUN mistakes and technical changes reserved...

Страница 8: ...olation Do not exceed the permissible voltage as indicated on the rating plate CAUTION Risk of piercing or puncture injury Mechanical hazard due to sharp test probes Maintenance work must be carried o...

Страница 9: ...hem and damage the test specimen Check all retention clamp positions to verify they have adequate clearance If clearance is insufficient use retention clamps with a smaller diameter or alternatively r...

Страница 10: ...e without protection outdoors or in a humid environment Ambient temperature 10 C to 75 C Humidity 85 do not allow condensation to form 12 2 Disposal Please bring the manual test fixture to a suitable...

Страница 11: ...10...

Страница 12: ...Stand 07 17 Index 1 1...

Отзывы: