3. Operating the display
The Ingecon
®
Sun Smart TL inverters are equipped with a « Keypad» unit for com-
munication with the installer and user.
This interface displays the principal internal parameters and the settings for adjusting the
entire system during installation.
The parameters, variables and commands are organized into a structure of menus and sub-
menus.
ESC
OK
3.1. Keypad and LEDs
The keypad comprises the following four keys:
ESC
Escape.
To exit the parameter edit mode, to exit a menu and return to a higher level, to not confirm
a change or not accept a proposal.
Up.
To scroll up a list of parameters or folders within the same level, or to increase the value of an
editable parameter by one basic unit.
Down.
To scroll down a list of parameters of folders within the same level, or to decrease the value
of an editable parameter by one basic unit.
OK
OK.
To validate a parameter change, to access a lower level menu, to confirm a change or accept
a proposal.
There are three LEDs on the faceplate, as follows:
Green LED
•
Flashing every 1 second: Start-up process.
•
Flashing every 3 seconds: On-hold status due to low radiation.
•
On: Inverter connected to the grid.
Orange LED
•
Flashing very 0,5 seconds: The external fan is not functioning correctly.
•
Flashing every 1 second: The internal fan is not functioning correctly.
•
Flashing every 3 seconds: The inverter is limiting the power due to high temperature.
•
On: An alarm has been triggered.
Red LED
•
On: Manual stop.
3.2. Display
The top line shows the current date and time. The internal clock
automatically makes the change from summer to winter time.
The central lines display the instant values for the solar array
voltage, power delivered by the inverter and the grid voltage and
frequency.
10:22
14/04/11
I.S. SMART 18.0 TL
STOP
C2
P=00000W
315V
235V 49.99Hz
319V
234V 50.00Hz
314V
235V 50.00Hz