Unit description
Ingeteam
ABS2011IQM01_G - Installation and Operation Manual
2.9. Specification table
100TL
DC inputs
Recommended power range of PV array
(1)
56 ~ 80.2 / 91,1 ~ 130.5 / 96.2 ~ 137.8 / 101.2 ~ 145 / 106.3 ~ 152.3 /
111.3 ~ 159.5 kWp
Maximum input voltage
(2)
1100 V (<1000 V to start production)
MPP Voltage range
513 / 541 / 570 / 599 / 627 ~ 850 V
Operating voltage range
513 / 541 / 570 / 599 / 627 ~ 1000 V
Minimum voltage for Pnom
513 / 541 / 570 / 599 / 627 V
Maximum short circuit current
240Adc
Maximum inverter backfeed current to the PV array.
1.7 kA
MPPT number
1
Number of strings (PRO version / STD version)
24 / 1
Maximum input current
185 Adc
Maximum input current per string
15 Adc
AC output
Rated power
90 / 95 / 100 / 105 / 110 kW
Maximum continuous power
90 / 95 / 100 / 105 / 110 kW
Max. temperature for rated power
50 ºC
Maximum current
145 A
Inrush current
<145 Arms 60ms
Maximum output fault current
<220 Arms 160 ms
Maximum output overcurrent protection
160 Arms
Rated voltage
400 V
Configurable rated voltages
360 / 380 / 400 / 420 / 440 V
Nominal frequency
50 / 60 Hz
Cosine of Phi
1
Adjustable cosine of phi
Yes. Smax = 100 kVA; Qmax = 60 kVAR
THD
(3)
<3%
Type of grid
TT, TN
Performance
Maximum efficiency
98.8%
Euroefficiency
98.5%
General data
Cooling system
Forced ventilation
Air flow
570 m
3
/h
Weight (PRO version / STD version)
78/75 kg
Dimensions (height x width x depth)
905 x 720 x 315 mm
Stand-by consumption
(4)
20 W
Night consumption
1 W
Operating temperature
-25 ºC ~ 60 ºC
Relative humidity (without condensation)
0 ~ 100%
Maximum altitude of the installation
3000 m (after 1000 m the maximum temperature decreases)
Protection class
IP65
Markings
CE
RCD
1000 mA
EMC and safety regulations
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-4, IEC 61000-3-11,
IEC62109-1, IEC62109-2, IEC62103, IEC 61000-3-12, EN50178, FCC
Part 15, IEC60068-2-1, IEC60068-2-2, IEC60068-2-14, IEC60068-2-30,
IEC60068-2-68, IEC 60529
Grid connection regulations
Arrêté du 23 avril 2008, VDE0126-1-1, EN 50549, CEI 0-16, VDE-AR-N
4105:2011-08, P.O.12.3, AS4777.2,BDEW, IEC 62116, IEC 61727, UNE
206007-1, ABNT NBR 16149, ABNT NBR 16150, Brazilian Grid code,
South African Grid code, Chilean Grid Code, DEWA 2.0, Chilean Grid Code,
Jordan Grid Code, Thailand MEA & PEA requirements
(1)
Depending on the type of installation and the geographic location.
(2)
Never exceed this value.
Consider the voltage increase of the panels ‘Voc’
at low temperatures.
(3)
For rated PAC and voltage according to
IEC 61000-3-4
.
(4)
Consumption from the PV array.
Содержание INGECON SUN 3Play 100TL
Страница 3: ...3 Ingeteam ABS2011IQM01_G Deutsch DE English EN Español ES Français FR Italiano IT Português PT ...
Страница 60: ...Anmerkungen Notes Notas Remarques Note Notas ...
Страница 170: ...Anmerkungen Notes Notas Remarques Note Notas ...
Страница 226: ...Anmerkungen Notes Notas Remarques Note Notas ...
Страница 336: ...Ingeteam Power Technology S A www ingeteam com ABS2011IQM01_G 09 2021 ...