Look for different temperatures between similar points (the three AC phases, for example). Differences in
temperature greater than 50 ºF (10 ºC) between similar points are considered abnormal.
If there is are abnormal measurements, contact Ingeteam.
Display and LED and led status (check, with voltage)
Check that the Display characters can be properly viewed, along with the access to the different menus.
Check that the LEDs light up correctly.
Voltage and current values (check, with voltage)
Check that the voltage and current values measured by the equipment are correct.
Firmware version of the unit and display (check, with voltage)
Access the
Inverter data
via the display menu.
11:23
30/10/15
11:23
30/10/15
The field
Firm
indicates that the unit´s firmware version. The field
FirmDis
indicates that the display´s firmware
version.
Check with Ingeteam if there are available updates of both firmware versions.
INFO
For more information on the firmware update process for the unit and display, see the video
Firmware upgrade
in the videos section of the INGECON SUN Training website (
http://www.ingeconsuntraining.info/?page_
id=3269
). The access data are:
Username: powermaxb
Password: Manual
22.3. Preventative replacement tasks
Preventative replacement tasks aim to replace components prior to their loss of function.
Preventative replacement tasks
Element
Replacement frequency
Fans
10 years
Motorized switch
3000 operations
Air filters
2 years or deterioration
AC thermomagnetic circuit breaker
12,500 operations
160
Maintenance
Ingeteam
Содержание INGECON SUN 1000TL U B360
Страница 1: ...INGECON SUN PowerMax TL U B 1000 Vdc Installation and Operation Manual...
Страница 22: ...ABK2027IQE01_A Installation and Operation Manual DC supply 22 Unit description Ingeteam...
Страница 176: ...Notes...
Страница 177: ...Notes...
Страница 178: ...Notes...
Страница 180: ...ABK2027IQE01_A 05 2019 Ingeteam Power Technology S A www ingeteam com...