USER MANUAL
MODEL NO.: TZ730–1710
Rev. 08 – 14 September 2005
APPENDIX C
FLOW CAPACITY & PURGE ADJUST
C2
3. PURGE ADJUSTMENT
To adjust the purge pressure, the following steps are to be followed. Refer also to the
flow schematics provided in section 7.
The power is turned on, the dryer is operating.
When either chamber is depressurized and being regenerated, adjust the
pressure on the pressure gauge using the purge adjusting valve supplied.
Refer to table below to adjust purge based on operating/inlet pressure.
TZ730
TZ820
TZ1050
TZ1200
TZ1450
TZ1710
P1
P2
P2
P2
P2
P2
P2
80
83
76
CF
80
74
80
90
85
80
90
82
78
82
100
86
81
90
82
81
85
110
86
81
97
82
77
82
120
88
CF
98
CF
CF
CF
NOTE: P1 = dryer inlet pressure (psig), P2 = dryer purge pressure (psig) based
on dryer inlet temperature (100°F), CF = consult factory.