6
18-BC99D1-1B-EN
Unit Location Considerations
Table 3. Suggested Locations for Best Reliability
•
Do not locate close to bedrooms as operational sounds may be
objectionable.
•
Avoid locations near windows and similar areas where
condensation and freezing defrost vapor can annoy a customer.
•
The
coil side
of the outdoor unit must be a minimum of 6” from
any wall or surrounding shrubbery to ensure adequate airflow.
Note: 2’ Required
for Service Panel
Access
Min. 20”
clearance to
obstruction
(Fan Side)
Min. 6” clearance
to obstruction
(Coil Side)
Airflow
Direction
Voltage
hook-up
Access panel
Note: 2’ Required
for Service Panel
Access
Min. 6”
clearance to
obstruction
(Coil Side)
Min. 20”
clearance to
obstruction
(Fan Side)
Airflow
Direction