![Ingersoll-Rand THERMO KING TriPac EVOLUTION Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/ingersoll-rand/thermo-king-tripac-evolution/thermo-king-tripac-evolution_installation-instructions_2059986002.webp)
2
8. Route the hourmeter harness to the TriPac control box, remove the control box cover and route
the harness through the large open slot in the base of the box.
9. Plug the hourmeter harness into connector
(J3)
on the PC board.
NOTE: All wiring should be neatly routed and secured with band wraps.
10. Reinstall control box cover.
11. Reconnect the TriPac’s
NEGATIVE (-)
cable at the tractor’s battery.
12. Operate the TriPac APU and the heater to verify hourmeter operation.
J3